Section 6: Keithley Interactive Test Environment (KITE)

Opening a UTM window

A UTM window allows you to enter information that defines a given UTM. A UTM window also
allows you to view and analyze test data created by the UTM, both numerically and graphically.
The Definition tab of the UTM window allows the user to specify a KULT created user
library and user module and then to specify a limited number of test parameters. The
included Formulator analysis tool allows you to perform calculations on test results and
include the calculation results in the Sheet tab Data worksheet (see below).
The Sheet tab displays the UTM results in its Data worksheet, in spreadsheet format. An
independent spreadsheet in the Sheet tab, the Calc worksheet, allows the user to perform
custom, test-specific data analysis. A third worksheet, the Settings worksheet, displays the
same settings information as in the Definition tab, but in spreadsheet format. Cells in the
Calc worksheet may be hot-linked to cells in the Data and Settings worksheets.
The Graph tab allows the user to create and export graphs of the test and test-analysis
results. The Graph tab provides for flexible plot-data selection, formatting, annotation, and
numerical coordinate display (using precision cursors).
The Status tab monitors the current configuration status of the UTM, reporting its readiness
for use and recommending additional preparations if necessary. A test-ready report for a
UTM is the same as for an ITM (to view example Status tab reports for ITMs, refer to
Status tab later in this
for an ITM. See the example in
Figure 6-161
Example Status tab report for an unconfigured UTM
To configure, or reconfigure, a UTM, you only need the Definition tab, which is the default tab of
the UTM window.
Open a UTM window as follows:
1.
In the Project Navigator, locate the UTM that you wish to configure. For illustration, the
res_drain-to-source UTM was selected from the u_build Project Plan (created under
Building a completely new Project
Figure 6-162
Opening a UTM Definition tab from the Project Navigator
2.
Double-click the UTM that you wish to configure (alternatively, if a Workspace window tab is
already displayed for the UTM to be configured (see the bottom of the UTM window), the
UTM is already open. Click the UTM Workspace window tab).
• If this is a completely new UTM, inserted into the Project Plan only by name and not yet
6-144
section). However, a test-not-ready report for a UTM is different than
connected to a user module, a blank UTM Definition tab appears. See
Return to
Figure
6-161.