Section 8: Keithley User Library Tool (KULT)
Table 8-16
Modifiers
Support
instr_id
KI_SYSTEM KI_TRIGMODE
SMUn
8-146
Parameters
modifier
value
KI_MEASX
KI_INTEGRATE
KI_AVERAGE
KI_ABSOLUTE
KI_NORMAL
KI_AVGNUMBER
<value>
KI_AVGTIME
<value>
(in units of
seconds)
KI_MX_DEFMODE
KI_HIGH
KI_LOW
KI_HICURRENT
KI_ON
KI_CC_AUTO
KI_ON
KI_OFF
KI_CC_SRC_DLY
<value>
KI_CC_COMP_DLY
<value>
KI_CC_MEAS_DLY
<value>
KI_INTGPLC
<value>
(in units of line cycles)
KI_AVGMODE
KI_MEASX
KI_INTEGRATE
Return to
Redefines all existing triggers to use a new
method of measurement.
Number of readings to take when
KI_TRIGMODE
Time between readings when
set to
Sets the default matrix mode to high current
mode or low current mode. This setting will
remain in effect until the end of the current
session and is not reset by devint.
Forces the matrix into high current mode. The
mode will revert to the default at the next devint
unless the configuration file sets this parameter to
reset on a clrcon.
Turns automatic compliance clear processing on
or off. devint will reset this value to
The minimum time after a source value change
before a compliance clear scan may start. This
represents the time after a source value change it
takes the circuit under test to settle and prevent
false compliance detection due to transients.
The time between compliance scans while
processing compclr. This also represents the
time after a source value change it takes the
circuit under test to settle and prevent false
compliance detection due to transients, but the
source value changes are only due to removing
instrument from an artificial compliance state.
The minimum time after the last source value
change before a measurement can be made.
This represents the time it takes the circuit under
test to settle to the level desired for the
subsequent measurements.
Specifies the integration time the SMU will use for
the intgx and sintgx commands. The default
devint value is 1.0. The valid range is 0.01 to
10.0.
Controls what kind of readings are taken for avgX
calls. The devint default value is
When
integration time used is that specified by the
KI_INTGPLC
Section Topics
Model 4200-SCS Reference Manual
Comment
is set to
KI_AVERAGE
KI_TRIGMODE
.
KI_AVERAGE
is specified, the
KI_INTEGRATE
setmode call.
4200-901-01 Rev. S / May 2017
.
is
.
KI_ON
.
KI_MEASX

Advertisement

Table of Contents
loading

Table of Contents