PTX1000 Alarm Messages Overview

When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the
management panel as appropriate. To view a more detailed description of the alarm cause, issue the
show chassis alarms CLI command:
user@host> show chassis alarms
2 alarms currently active
Alarm time
2017-01-23 02:39:29 PST
2017-01-23 02:39:29 PST

Chassis Alarm Messages on the PTX1000

Chassis alarms indicate a failure on the device or one of its components. Chassis alarms are preset and
cannot be modified.
Chassis alarms on PTX1000 routers have two severity levels:
Major (red)—Indicates a critical situation on the device that has resulted from one of the conditions
described in
Table 31 on page
Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left unchecked, might
cause an interruption in service or degradation in performance. A yellow alarm condition requires
monitoring or maintenance.
Table 31 on page 116
describes the chassis alarm messages on the PTX1000.
Class
Description
Major
PEM 3 Not Present
Major
PEM 1 Not Present
116. A red alarm condition requires immediate action.