Operation Diagrams - BONFIGLIOLI Active ACT 201-05 Brief Manual

230 v / 400 v 0.55 kw ... 30.0 kw
Table of Contents

Advertisement

3.5
The technical data of the frequency inverters refer to the nominal point which was
selected to enable a wide range of applications. A functionally and efficient
dimensioning (derating) of the frequency inverters is possible based on the following
diagrams.
Power reduction (Derating),
5%/1000 m above sea level,
h = 4000 m
14
14

Operation diagrams

max
100
85
60
40
20
1000
2000
Mounting altitude in m above sea level
Power reduction (Derating)
2.5%/K upper 40 °C, T = 55 °C
100
80
63
40
20
reduction of output current at constant power (Derating)
0.22%/ V upper 400 V, U = 480 V
100
83
63
40
20
0
Site altitude
max. coolant temperature,
3.3 °C/1000 m above sea level,
55
45
3000
4000
Mounting altitude in m above sea level
Coolant temperature
max
0
10
20
30
40
Coolant temperature in °C
Mains voltage
max
400 420 440 460
Mains voltage in V
3000
2000
1000
50
55
480
4000
06/05
06/05