7 R
ECORDINGS
Position Description
17
RESP Size
18-19
minutes since breath
detector initialization
20
Not Used
21
Monitor Model
22-26
Software Version

Timed Recordings

Timed recordings are strip recordings of a specified duration (from 6 to 20 seconds).
They contain delay data that originated before the recording was initiated and real-
time data that was acquired after the recording started.
Alarm limit violations and arrhythmia events trigger a timed recording automatically,
if the recording and/or alarm function has been enabled on the Alarm Limits table, the
ST Alarms menu, or the Arrhythmia Setup menu (see chapter 5, Alarms).
To request a timed recording
Press the
To cancel a timed recording
Press the
7-6
Values
1-K
00-99
<Space>
A
B
I
J
T
XXXX
(ASCII)
fixed key on the front of the monitor.
Record
fixed key again or the recorder's
Record
D
/D
ELTA
ELTA
Definition
Value = (RESP Size)/5
(where A-K corresponds to 10-20)
Number of minutes that have elapsed since the
breath detector was initialized
(where 99 corresponds to >= 99 minutes)
Not applicable
SC9000
Delta/Delta XL/Kappa
SC6000
Gamma
Infinity Telemetry
First 5 characters of base software
(i.e. "VA1.1")