Dräger recommends that:
Maintenance, modifications, and repairs are carried out by trained personnel.
Components are replaced with Dräger provided spare parts, otherwise the
correct functioning of the device may be compromised.
Devices are used in accordance with Dräger Instructions for Use.
General Electrical Safety
WA R N I N G :
CAUTION: To avoid injuring the patient, do not touch any connector or mounting
screw on the device when you are touching the patient. Do not allow the conductive
parts of electrodes and cables to ever contact other conductive parts or ground, either.
NOTE: The potential equalization terminal can help ensure that a voltage difference
does not exist between multiple pieces of equipment.
10
S
U
'
ERIES
SER
To p r o t e c t t h e pa t i e n t f r o m p o s s i b l e i n j u r y d ue t o
e l e c t r i c a l s h o c k :
B e f or e p u t t i n g a pa t i e n t m o n i t o r i n t o u s e , t h e i n s ta l l e r
m u s t v e r i f y t ha t i ts l e a k a g e c ur r e n t m e e ts t h e e l e c t r i c a l
s a f e t y r e q ui r e m e n ts o f I E C 6 0 6 0 1 - 1 a n d I E C 6 0 6 0 1 - 1 - 1
( t h e s a f e t y s ta nd a r d s f o r M e d i c a l E l e c t r i c a l S y s t e m s ) .
C o n n e c t i n g s e v e r a l m e d i c a l d e v i c e s t o a pa t i e n t
s i m u l ta n e o u s l y i n c r e a s e s t h e l e a k a g e c u r r e n t t o w h i c h
t h a t pa t i e n t i s e x p o s e d . P e r i p h e r a l d e v i c e s s h o u l d o n l y
b e c o n n e c t e d t o a pa t i e n t m o n it or w i t h i n t h e s a m e
r o o m.
T he i n s ta l l e r o r s e r v i c e p ro v i d e r s h o u l d v e r i f y t h a t t h e
i n t e r c o n n e c t e d s y s t e m 's l e a k a g e c u r r e n ts m e e t t h e
e l e c t r i c a l s a f e t y r e q ui r e m e n ts m e n t i o n e d a bo v e . T he
i n s ta l l e r o r s e r v i c e p ro v i d e r s h o u l d a l s o v e r i f y t h a t t h e
e l e c t r i c a l s a f e t y c l a s s i f i c a t i o n o f e a c h d e v i c e i s
s u i ta b l e f o r t he i n t e n d e d a p p l i c a t i o n .
To a v o i d e l e c t r i c s h o c k , i n s p e c t a l l c a b l e s b e f o r e u s e .
N e v e r u s e c a b le s t h a t a p p e a r c r a c k e d , w or n , o r
d a m a g e d i n a n y w a y ( d o i n g s o m a y c om p r o m i s e
p e r f o r m a n c e o r p u t t h e pa t i e n t a t r i s k ) .
To e n s u r e t h a t t h e d e v i c e i s p r o p e r l y g ro u n d e d ,
c o nn e c t t h e A C a d a p t e r, c o m m u n i c a t i o n p o w e r s u p p l y
m o d u l e , a n d I D S p o w e r s u p p l y t o a h o s p i ta l - g r a d e
o u t l e t .