Sign In
Upload
Manuals
Brands
Dräger Manuals
Medical Equipment
Infinity Acute Care System M540
Dräger Infinity Acute Care System M540 Manuals
Manuals and User Guides for Dräger Infinity Acute Care System M540. We have
5
Dräger Infinity Acute Care System M540 manuals available for free PDF download: Instructions For Use Manual, Quick Reference Manual
Dräger Infinity Acute Care System M540 Instructions For Use Manual (610 pages)
Acute care system
Brand:
Dräger
| Category:
Medical Equipment
| Size: 11 MB
Table of Contents
Table of Contents
7
Mainstream CO
2
Open-Source Software
4
Definition of Target Groups
6
Table of Contents
7
For Your Safety and that of Your Patients
13
Strictly Follow These Instructions for Use
14
Storing the Instructions for Use
14
Training
14
Maintenance
14
Accessories
14
Installing Accessories
15
Sterile Accessories
15
Restriction of Distribution
15
Restrictions for Use
15
Connected Devices
15
Safe Connection with Other Electrical
15
Equipment
15
Electrical Safety
16
Connection to Hospital Network
16
Patient Safety
16
Patient Monitoring
17
General Safety Information
18
Not for Use in Areas of Explosion Hazard
19
Information on Electromagnetic Compatibility
19
Operating Location
19
Defibrillator Precautions
20
Electrosurgery
20
Virus Protection
20
Security Recommendations
21
Application
23
Intended Use
24
Indications for Use
24
System Overview
25
Infinity Medical Cockpit
26
Overview
26
Infinity P2500 Power Supply Unit (P2500)
27
Infinity PS250 Power Supply Unit (PS250)
27
Infinity M500 Docking Station (M500)
28
Front View of the M500
28
Infinity M540 Patient Monitor (M540)
28
Additional Hardware
29
Rear View of the M500
29
Device Symbols
32
Abbreviations
36
Operating Concept
43
Overview
44
The IACS Components
45
M540 and Cockpit Communication
46
Docking the M540
46
Undocking the M540
47
Communicating with the Infinity Network
48
Loss of Connection to the Network
48
M540 in Standalone Mode
48
Network Data Transfer
49
Remote Control and Remote View
51
Remote View from the Cockpit
51
Central Monitoring
53
Network Communication Interruptions
53
Communication Management
54
Remote Control
54
IT Applications
54
Loss of Power
57
Locked Options
57
Temporary Options
57
Secondary Display
58
Export Protocol
58
User Interface
59
Header Bar
60
Monitoring Area
61
Parameter Fields
62
Waveforms
62
Supported Messages
63
Freezing/Stopping Waveforms
63
Dialogs and Pages
64
Main Menu Bar and Quick Access Toolbar
65
Main Menu Bar
65
Quick Access Toolbar
66
Filtering the Parameter Content
67
Auto and Manual Display Modes
67
Auto View Mode
67
Manual View Mode
67
Auto View Setup Toolbar
68
Customizing the Display
68
Screen Brightness
68
Touchscreen Versus Mouse
68
Calibrating the Touchscreen
68
Cockpit Screen in Split Screen Mode
69
Cockpit Split Screen Mode with Mini-Trends
70
Cockpit Split Screen Mode with Multi-Tab Split
71
Screen
71
Cockpit Split Screen Mode with Mini-Trends
72
And IT Tabs
72
Parameter Priority
73
Configuring the Parameter Priority and Display
73
Parameter Priority List
73
Views
74
Selecting a View
74
The View Editor
74
Profiles/Status
75
Patient and Default Profiles
75
Settings Included in a Profile
76
Settings Not Included in a Profile
81
System Profiles
82
Managing Profiles and Views
86
Transferring Profiles
86
Standby Mode
87
Privacy Mode
88
Screen Lock
89
Assembly and Preparation
91
Assembly Overview
92
Docking/Undocking the M540
93
Front View of the M500 (M540 Docked)
93
Side View of the M500 (M540 Undocked)
93
Locking/Unlocking the M540
94
Additional M540 Accessories
95
Connecting the System Cables
95
P2500 and the Cockpit
95
P2500 and the M500
96
Mounting the Infinity Mcable - Masimo Set/Masimo Rainbow SET/ Nellcor Oximax
97
Getting Started
99
Overview
100
Turning the IACS On/Off
100
Viewing Demographic Data
101
Admitting a Patient
102
Discharging a Patient
103
Admitting a Patient Using Get HIS
103
Patient Categories
104
Selecting the Patient Category
105
Alarms
107
Overview of Alarms
108
Acoustic Alarm Signals
108
Alarm Priorities
109
Alarm Processing
109
High-Priority Alarm Conditions
109
Medium-Priority Alarm Conditions
109
Low-Priority Alarm Conditions
109
Multiple Alarm Conditions
110
Testing Optical and Acoustic Alarm Signals
110
Viewing Current Alarm Messages
110
Activating or Deactivating Alarm Validation
111
ASY/VF Alarms
111
Optical Alarm Signals
112
Alarm Bar
113
Cardiac Bypass Mode
113
Acoustic Alarm Signals
114
Pre-Silencing Alarms
114
Attention Tones
115
Special Conditions
115
Testing Optical and Acoustic Alarm Signals
116
Viewing Current Alarm Messages
116
Deactivating the Alarm Volume
116
Special Alarm Behavior
117
Spo2 Desaturation Alarms
117
Nibp/Spo 2 Interlock Alarms
117
Pausing Alarm Monitoring Temporarily
117
Zeroing Invasive Blood Pressures
118
Privacy Mode
118
Standby Mode
118
OR Alarms
119
French NFC Mode
119
Activating/Deactivating Alarms
119
Pre-Silencing Alarms
120
Initiating a Pre-Silence Period
120
Pausing Acoustic Alarm Signals (Audio Pause)
121
Quiet Mode
121
Configuring the Alarm Setup for an Individual Pa- Rameter
121
Activating or Deactivating Acoustic Alarm Signals
123
Pausing Alarm Monitoring Temporarily
123
Activating or Deactivating Alarm Monitoring
124
Configuring the Alarm Settings for a Patient
125
Setting the Upper and Lower Alarm Limits
126
Configuring the Alarm Setup for an Individual Parameter
127
Configuring ARR Alarm Settings
128
Configuring the Alarm Setup for Multiple Parameters
129
Alarm Setup for ST
129
Configuring the Alarm Message Behavior
131
Configuring ST Alarm Settings
131
Configuring the Arrhythmia Alarm Setup
134
Alarm Setup for ST
135
Auto Setting All Alarm Limits
138
Alarm History and Stored Events
139
Viewing a Snapshot of a Single Event
141
Configuring Alarm Settings Temporarily
142
Viewing Current Alarms
142
Configuring the Spo2 Alarm Priority
143
Configuring the Alarm Priority for a Masimo Sen
143
Remote Alarm Control
144
Configuring the Alarm Priority for a Nellcor Check Sensor Message
144
Alarm Groups
145
Infinity Mcable - Nurse Call
146
External Device Disconnection Alarm
147
The Code Function
147
The Timer Function
148
Alarm Ranges and Defaults
149
Alarm Priority
160
Trends/Data Dialogs
161
Overview
162
Trending Behavior
162
Supported Parameters
162
Graphical Trends
164
Special Characters and Symbols
164
The Layout of the Graphical Trends Pages
165
Pages
166
Interacting with the Graphical Trends Pages
166
Configuring the Parameter Content of the Graphical Trends
166
Navigating through the Graphical Trends
167
Using the Cursor
167
Changing Trend Scales
168
General Graphical Trend Display Features
168
Printing a Graphical Trend Report
168
Analysis Tool Page
169
The Layout of the Analysis Tool Page
169
Interacting with the Analysis Tool Page
170
Configuring the Parameter Content
170
Using the Cursors
171
Freezing the Display
171
Tabular Trend
172
Selecting an Interval
172
Printing an Analysis Tool Graphical Trend
172
Report
172
The Layout of the Tabular Trend
173
Interacting with the Tabular Trend
174
Tabular Trends in Split Screen Mode
174
Navigating through the Tabular Trend
174
Configuring the Tabular Trend
174
Configuring the Parameter Content of the Tabular Trend
175
Mini-Trends
176
Printing a Tabular Trend Report
176
Configuring the Mini-Trend Display
176
Data Review Pages
177
Reports Tab
179
Calculations
181
Overview
182
Calculating the Body Surface Area
182
Accessing the Calculation Functions
183
Performing Calculations
183
Viewing the Calculation Results
185
Viewing and Saving Calculations
185
Laboratory Data
186
Capturing Laboratory Data
186
Calculation Equations
187
Hemodynamic Parameters
187
Oxygenation and Ventilation Parameters
189
Accessing the Drug Calculation Functions
191
Drug Calculations
191
Customized Drug List
192
Performing Drug Calculations
192
Customizing the Drug List
193
Drug Calculator Equations
194
Ecg, Arrhythmia, and St Segment
197
Overview of ECG and Heart Rate Monitoring
199
Monitoring
199
ECG Signal Processing and Display
199
Supported Parameters
199
ECG Precautions
200
Connecting the 3-, 5-, 6-Wire Lead Sets for ECG Monitoring
201
Connecting the Lead Sets for 12-Lead Monitoring
202
Connecting the Lead Wires for Neonatal Monitoring
203
Monitoring
203
Patient Preparation for ECG Monitoring
204
Monitoring
204
Electrosurgery
204
ECG Display
205
ECG Parameter Field
205
ECG Waveforms
206
ECG Colors
207
Electrode Placement
208
Standard Configuration, Three Electrodes
208
(Iec/Aha)
208
Standard Configuration, Five Electrodes
208
Pacer Configuration, Five Electrodes
209
(Iec/Aha)
209
Standard Configuration, Six Electrodes
209
12-Lead Configuration, Ten Electrodes for 12-Lead Rest ECG Monitoring (AHA)
210
12-Lead Configuration, Ten Electrodes for 12-Lead Rest ECG Monitoring (IEC)
210
12-Lead Monitoring
211
Accessing the ECG Functions
211
ECG Parameter Setup Functions
212
Monitoring Paced Patients
216
Pacemaker Precautions
217
Pacer Fusion Mode
217
Device Interference with Pacemaker
218
Monitoring
218
Arrhythmia Monitoring Overview
219
Optimizing Pacer Processing
219
Selecting Arrhythmia Leads
220
Arrhythmia Modes
221
Arrhythmia Processing
221
Arrhythmia Display
223
Combined Heart Rate /Arrhythmia Parameter
224
Field
224
Separate Arrhythmia Parameter Field
224
Accessing the Arrhythmia Functions
225
Arrhythmia Parameter Setup Functions
225
Monitoring ST Overview
226
Standard ST Monitoring
226
12-Lead ST Monitoring
227
Connecting Lead Sets for ST Monitoring
227
Trust 12-Lead Monitoring
227
ST Display
228
Reviewing ST Complexes
229
Reviewing All ST Complexes
229
Zooming in on an ST Complex
230
ST Measuring Points
231
Adjusting ST Measuring Points
231
ST Reference
232
Saving ST Reference Points
232
Accessing the ST Settings
233
ST Alarm Settings
233
ST Setup Functions
234
Learning/Relearning QRS Pattern
236
Manual Relearning
236
Impedance Respiratory Rate (Rri)
239
Overview of Respiration Monitoring
240
Respiration Precautions
240
Supported Parameter
240
Connecting the 3-, 5-, 6-Wire Lead Sets for Respiration Monitoring
241
Connecting the Lead Sets for 12-Lead Monitoring
242
Monitoring
242
Connecting the Lead Wires for Neonatal Monitoring
243
Monitoring
243
Patient Preparation for Respiration Monitoring
244
Monitoring
244
Respiration Display
246
Ventilation Parameter Field
246
Breath Markers
246
Adjusting the Detection Threshold and Activating the Breath Marker
247
Respiration Measuring Modes
247
Accessing the Respiration Settings
248
Ventilation Parameter Setup Functions
248
Spo2 and Pulse Co-Ox Monitoring with Masimo Set Mcable
251
Masimo SET Mcable
251
Overview of Spo2 and Pulse CO-Ox Monitoring
252
Monitoring
252
Supported Parameters
252
Spo2 and Pulse CO-Ox Precautions
254
Connecting the Masimo SET Mcable
256
Connecting the Masimo Rainbow SET
257
Mcable
257
Patient Preparation
258
Applying the Sensor
258
Spo2 and Pulse CO-Ox Display
259
Parameters
259
Reviewing the Spo2 and Pulse CO-Ox Parameters
262
Accessing the Spo2 Settings
263
Spo2 Parameter Setup Functions
264
Masimo Rainbow SET Pulse CO-Ox Parameter Setup Functions
266
Password-Protected Masimo Rainbow SET
269
Setup Functions
269
SET Setup Functions
269
Spo2 and Pulse Rate with Nellcor Oximax Mcable
271
Mcable
271
Overview of Spo2 Monitoring
272
Supported Parameters
272
Spo2 Precautions
273
Connecting the Nellcor Oximax Mcable
274
Patient Preparation for Spo Monitoring
275
Patient Preparation for Spo 2 Monitoring
275
Applying the Sensor
276
Spo2 Display
277
Spo2 Parameter Field
277
Accessing the Spo2 Settings
278
Spo2 Parameter Setup Functions
278
Temperature
281
Overview of Temperature Monitoring
282
Precautions
282
Connecting the Temperature Sensors
283
M540
284
Connecting the Temperature Sensors to the Hemodynamic Pods
285
Temperature Display
286
Temperature Parameter Field
286
Accessing the Temperature Settings
287
Temperature Parameter Setup Functions
287
Advertisement
Dräger Infinity Acute Care System M540 Instructions For Use Manual (350 pages)
Patient Monitor
Brand:
Dräger
| Category:
Medical Equipment
| Size: 6 MB
Table of Contents
For Your Safety and that of Your Patients
5
Patient Preparation for Spo
2
Table of Contents
5
Maintenance
6
Storing the Instructions for Use
6
Strictly Follow These Instructions for Use
6
Training
6
Accessories
7
Connected Devices
7
Installing Accessories
7
Restriction of Distribution
7
Restrictions for Use
7
Safe Connection with Other Electrical Equipment
7
Safety Checks
7
Sterile Accessories
7
The Medical Device Must be Subject to Regular Safety Inspections. See Chapter "Maintenance
7
Device Combinations
8
Connection to Hospital Network
9
General Safety Information
9
Patient Monitoring
9
Patient Safety
9
Information on Electromagnetic Compatibility
11
Not for Use in Areas of Explosion Hazard
11
Site of Operation
11
Defibrillator Precautions
12
Electrosurgery
12
Table of Contents
13
Contents
13
Application
17
Intended Use
18
Indications for Use
19
Functional Safety
19
Overview Overview
21
Overview
21
Overview
22
M540 Front Panel
23
M540 Back Panel
24
M540 Side Panel
24
M500 Docking Station
25
M500 Front Panel
25
M500 Back Panel
25
Additional Hardware
26
M540 Docked in the M500
26
Symbols
28
Wireless Symbols
30
Abbreviations
31
Operating Concept
33
Overview
34
M540 in Standalone / Wireless Mode
34
Configuration Changes While on Wireless
35
Transport
35
Bed Label Setting
36
Network Status Symbol
36
M540 in an IACS Configuration
37
Communicating with the Infinity Network
37
ICS (Infinity Centralstation) Communication
38
Loss of Connection to the Network
38
ICS (Infinity Centralstation)
38
Communication
38
Audio Pause Feature
40
Network Communication Interruptions
40
Network Data Transfer
40
Remote View and Remote Control
41
Function Keys
43
Default Function Key Assignments
43
Monitoring Area
44
Alternate Function Key Assignments
44
Header Bar
44
The Alarm Banner Field
45
Parameter Boxes
46
Waveforms
46
Dialog Windows
47
Adjusting the Display
48
Calibrating the Touch Screen
48
Battery Power
49
Battery Charging Times
49
Battery Operating Times
49
Low Battery Conditions
49
Views
50
Selecting a View
50
Power-Saving Mode
50
Profiles
51
Settings Included in a Profile
52
Alarm Profile Settings
52
CO 2 Profile Settings
53
Heart Rate and Arrhythmia Profile Settings
55
ST Profile Settings
56
Respiration (Rri) Profile Settings
56
Spo 2 (Masimo) Profile Settings
57
Pulse CO-Ox (Masimo) Profile Settings
58
Spo 2 (Nellcor) Profile Settings
58
Non-Invasive Blood Pressure Profile Settings
59
Temp Profile Settings
59
Invasive Blood Pressure Profile Settings
60
Monitor Settings
61
Settings Not Included in a Profile
62
Saving a Profile
63
Profile Behavior in a Standalone Configuration
64
Profile Behavior in an IACS Configuration
63
Configuration
64
Profile Adoption
64
Different Profile Configurations
65
Use-Case Scenario
65
Standby Mode
66
Privacy Mode
66
Recordings/Reports
67
Timed, Continuous, and Stored Recordings
67
Rest ECG Reports
68
Assembly and Preparation
69
Overview
70
Commercially Available M500 Mounting
70
Solutions
70
Docking/Undocking the M540
71
M500 Front View with M540 Docked
71
M500 Side View (M540 Undocked)
71
Locking/Unlocking the M540
72
Configuration
73
Connecting the System Cables in an IACS Configuration
73
Connecting the System Cable in an M540 Stand-Alone Configuration
73
Mounting the Infinity Mcable - Masimo
74
Mounting the Infinity Mcable - Masimo SET and Masimo Rainbow Set/Nellcor Oximax
74
Oximax
74
SET and Masimo Rainbow Set/Nellcor
74
Getting Started
77
Overview of Monitoring a Patient
78
Turning the M540 On/Off
78
Admitting a Patient
79
Discharging a Patient
80
Admitting a Patient Using 'Get HIS
80
Patient Categories
81
Selecting a New Patient Category
81
Alarms
83
Overview of Alarms
84
Alarm Priorities
84
High-Priority Alarm Conditions
84
Alarm Processing
85
Medium-Priority Alarm Conditions
85
Low-Priority Alarm Conditions
85
Latching and Non-Latching Alarm Behavior
85
Activating or Deactivating Alarm Validation
86
Multiple Alarm Conditions
86
Visual Alarm Signals
87
Acoustic Alarm Signals
88
Alarm Bar
88
Attention Tones
90
Adjusting the Alarm Volume
90
Testing Visual and Acoustic Alarm Signals
90
Special Alarm Behavior
91
Arrhythmia/Ventricular Fibrillation Alarms
91
Spo 2 Desaturation Alarm Feature
91
Nibp/Spo 2 Interlock Alarm Feature
91
Zeroing Invasive Blood Pressures
91
Privacy Mode
92
Standby Mode
92
OR Mode
93
Cardiac Bypass Mode
93
French NFC Mode
93
Pre-Silencing Alarms
94
Initiating a Pre-Silence Period
94
Pausing Acoustic Alarm Signals (Audio Pause)
95
Pause)
95
Quiet Mode
95
Pausing Alarms at the M540
96
Pausing Acoustic Alarm Signals
95
Pausing Alarm Monitoring Temporarily
97
Activating or Deactivating Alarm Monitoring
98
Configuring a Patient's Alarm Settings
98
Monitoring
98
Setting the Upper and Lower Alarm Limits
99
Using the Auto Set Function
100
Auto Set All
100
Activating/Deactivating Alarms
101
Archive Function
101
Event Recall
102
Viewing Stored Events
103
Viewing a Snapshot of a Single Event
104
Configuring the Spo
105
Alarm Priority
105
Configuring the Alarm Priority for the Masimo Sensor off Message
105
Configuring the Alarm Condition for the Nellcor Check Sensor Message
105
Protected)
106
Alarm Groups
106
Alarm Management Setup
106
The Code Function Key
106
Alarm Ranges and Defaults
107
Arrhythmia Ranges and Defaults
114
Impedance Respiration (Rri)
115
Overview of Respiration Monitoring
116
Rri Precautions
116
Supported Parameters
116
Connecting the 3-, 5-, 6-Lead Wire Sets for Respiration Monitoring
117
Connecting the Lead Wire Sets for 12-Lead Respiration Monitoring
118
Connecting the Lead Wires for Neonatal Respiration Monitoring
119
Patient Preparation for Respiration Monitoring
120
Monitoring
120
Respiration Display
122
Respiration Parameter Box
122
Respiration Markers
122
Respiration Measuring Modes
123
Accessing the Respiration Dialog Window
123
Respiration Parameter Setup Functions
124
Ecg, Arrhythmia, and St Segment
127
Overview of ECG and Heart Rate Monitoring
129
Monitoring
129
ECG Signal Processing and Display
129
ECG Precautions
130
Supported Parameters
130
Connecting the 3-, 5-, 6-Lead Wire Sets for ECG Monitoring
131
Connecting the Lead Wire Sets for 12-Lead ECG Monitoring
132
Connecting the Lead Wires for Neonatal ECG Monitoring
133
ECG Monitoring
133
Patient Preparation for ECG Monitoring
134
Electrosurgery
134
ECG Display
135
ECG Parameter Box
135
ECG Waveforms
135
ECG Electrode Colors
136
Electrode Placement
137
Standard Configuration, Three Electrodes (IEC/AHA)
137
Standard Configuration, Five Electrodes
137
(Iec/Aha)
137
Pacer Configuration, Five Electrodes
138
(Iec/Aha)
138
Standard Configuration, Six Electrodes
139
(Iec/Aha)
139
12-Lead Configuration, Ten Electrodes for 12-Lead Rest ECG Monitoring (AHA)
139
12-Lead Monitoring
140
12-Lead Configuration, Ten Electrodes for 12- Lead Rest ECG Monitoring (IEC)
140
Accessing the ECG Dialog Window
141
ECG Parameter Setup Functions
141
Monitoring Paced Patients
144
Pacemaker Precautions
145
Pacer Fusion Mode
146
Device Interference with Pacemaker
146
Monitoring
146
Arrhythmia Monitoring Overview
147
Optimizing Pacer Processing
147
Selecting Arrhythmia Leads
148
Arrhythmia Modes
149
Arrhythmia Processing
149
Arrhythmia Display
151
Arrhythmia Basic Parameter Box
151
Accessing the Arrhythmia Dialog Window
152
Arrhythmia Parameter Setup Functions
152
Monitoring ST Overview
153
Standard ST Monitoring
153
12-Lead ST Monitoring
154
Trust 12-Lead Monitoring
154
Connecting Lead Wire Sets for ST Monitoring
155
ST Display
155
Monitoring
155
ST Complex Dialog Windows
156
Zooming in on a Single ST Complex
156
ST Measuring Points
157
ST Reference
157
Adjusting ST Measuring Points
157
Saving ST Reference
157
Accessing the ST Dialog Window
158
ST Setup Functions
158
Learning/Relearning QRS Pattern
160
Manual Relearning
160
Dräger Infinity Acute Care System M540 Instructions For Use Manual (292 pages)
Acute Care System Patient Monitor with VG2 Software
Brand:
Dräger
| Category:
Personal Care Products
| Size: 1 MB
Table of Contents
Table of Contents
5
Patient Preparation for CO 2 Monitoring
2
Table of Contents
5
Strictly Follow These Instructions for Use
10
Training
10
Safety Inspections and Maintenance
10
Safety Inspections
10
Accessories
11
Installing Accessories
11
Sterile Accessories
11
Restrictions for Use
11
Connected Devices
11
Safe Connection with Other Electrical
11
Equipment
11
Networking and Connection to Other Devices
11
Connection to Hospital Network
12
Patient Safety
12
Patient Preparation for Spo
2
For Your Safety and that of Your Patients
13
General Safety Information
13
Not for Use in Areas of Explosion Hazard or in Oxygen-Enriched Areas
13
Information on Electromagnetic Compatibility
14
Site of Operation
14
Defibrillator Precautions
14
Electrosurgery
15
Intended Use
17
Infinity M540
18
System Overview
19
Overview of Infinity M540
20
M540 Front Panel
21
M540 Back Panel
22
M540 Side Panel
22
Infinity M500 Docking Station
23
M500 Front Panel
23
M500 Back Panel
23
Additional Hardware
24
M540 Docked in the M500
24
Device Symbols
26
Wireless Symbols
27
Abbreviations
28
Operating Concept
31
M540 Wireless Mode
32
Communicating with the Infinity Network
33
ICS (Infinity Centralstation) Communication
33
Network Communication Interruptions
34
Remote Control
35
Recordings for M540 on Wireless Transport
36
Overview
32
Function Keys
37
Default Function Key Assignments
37
Monitoring Area
38
Alternate Function Key Assignments
38
Header Bar
38
Parameter Boxes
39
Waveforms
39
Dialog Windows
40
Adjusting the Display
41
Calibrating the Touch Screen
41
Battery Power
42
Battery Charging Times
42
Battery Operating Times
42
Low Battery Conditions
42
Power-Saving Mode
43
Views
43
Selecting a View
43
Profiles
44
Standby Mode
45
Privacy Mode
46
Assembly
47
Overview
48
Commercially Available M500 Mounting
48
Solutions
48
Docking/Undocking the M540
49
Front View
49
Side View
49
Locking/Unlocking the M540
50
Configuration
51
Connecting the System Cables in an IACS Configuration
51
Connecting the System Cable in an M540 Stand-Alone Configuration
51
Mounting the Infinity Mcable - Masimo
52
Mounting the Infinity Mcable - Masimo SET
52
Mcable
52
Oximax Mcable
52
SET and Masimo Rainbow Set/Nellcor
52
Getting Started
55
Overview of Monitoring a Patient
56
Turning the M540 On/Off
56
Admitting a Patient
57
Discharging a Patient
58
Patient Categories
58
Selecting a New Patient Category
59
Alarms
61
Alarm Priorities
62
High-Priority Alarm Conditions
62
Medium-Priority Alarm Conditions
62
Low-Priority Alarm Conditions
62
Overview of Alarms
62
Alarm Processing
63
Latching and Non-Latching Alarm Behavior
63
Multiple Alarm Conditions
63
Activating or Deactivating Alarm Validation
64
Visual Alarm Signals
65
Alarm Bar
66
Acoustic Alarm Signals
67
Testing Visual and Acoustic Alarm Signals
68
Special Alarm Behavior
68
Adjusting the Alarm Tone
68
ASY/VF Alarms
68
Spo 2 Desaturation Alarms
69
Nibp/Spo 2 Interlock Alarms
69
Privacy Mode
69
Standby Mode
69
OR Mode
69
Cardiac Bypass Mode
69
Pre-Silencing Alarms
70
Pausing Acoustic Alarm Signals
70
French NFC Mode
70
Pausing Alarm Monitoring Temporarily
71
Activating or Deactivating Alarm
72
Activating or Deactivating Alarm Monitoring
72
Monitoring
72
Configuring a Patient's Alarm Settings
73
Setting the Upper and Lower Alarm Limits
73
Using the Auto Set Function
74
Activating/Deactivating Alarms
75
Archive Function
75
Event Recall
76
Viewing Stored Events
76
Viewing a Snapshot of a Single Event
77
Tected)
78
The Code Function Key
78
Alarm Groups
78
Alarm Management Setup
78
Protected)
78
Alarm Ranges and Defaults
79
Arrhythmia Ranges and Defaults
85
Ecg, Arrhythmia, and St Segment
87
Overview of ECG and Heart Rate Monitoring
89
ECG Signal Processing and Display
89
Supported Parameters
89
Connecting the 3-, 5-, 6-Lead Wire Sets for ECG Monitoring
89
Connecting the 3-, 5-, 6-Lead Wire Sets for ECG Monitoring
90
Connecting the Lead Wire Set for 12-Lead ECG Monitoring
90
ECG Precautions
90
Connecting the Lead Wire Set for 12-Lead ECG Monitoring
91
Connecting the Lead Wires for Neonatal ECG Monitoring
92
Patient Preparation for ECG Monitoring
92
Patient Preparation for ECG Monitoring
93
Electrosurgery
93
ECG Parameter Box
93
ECG Waveforms
93
ECG Display
94
Pacer Configuration, Five Electrodes
94
ECG Electrode Colors
95
Electrode Placement
95
Standard Configuration, Six Electrodes
95
12-Lead Configuration, Ten Electrodes for 12-Lead Rest ECG Monitoring
96
12-Lead Monitoring
96
12-Lead Monitoring
98
Accessing the ECG Dialog Window
98
ECG Parameter Setup Functions
98
ECG Parameter Setup Functions
99
Monitoring Paced Patients
101
Pacer Fusion Mode
101
Monitoring Paced Patients
102
Pacemaker Precautions
102
Device Interference with Pacemaker
103
Monitoring
103
Arrhythmia Monitoring Overview
103
Optimizing Pacer Processing
104
Arrhythmia Monitoring Overview
105
Selecting ARR Leads
105
ARR Modes
106
ARR Basic Parameter Box
107
ARR Display
108
Accessing the ARR Dialog Window
108
ARR Parameter Setup Functions
108
Accessing the ARR Dialog Window
109
ARR Parameter Setup Functions
110
Monitoring ST Overview
110
Standard ST Monitoring
110
Trust 12-Lead Monitoring
111
12-Lead ST Monitoring
111
12-Lead ST Monitoring
112
Connecting Lead Wire Sets for ST Monitoring
112
ST Display
112
ST Complex Dialog Windows
113
Zooming in on a Single ST Complex
113
Trust 12-Lead Monitoring
112
ST Complex Dialog Windows
114
ST Measuring Points
114
ST Reference
114
Adjusting ST Measuring Points
114
Saving ST Reference
114
Accessing the ST Dialog Window
115
ST Setup Functions
115
Learning/Relearning QRS Pattern
117
Manual Relearning
117
Impedance Respiration (Rri)
119
Overview of Rri Monitoring
120
Rri Precautions
120
Supported Parameters
120
Connecting the 3-, 5-, 6-Lead Wire Sets for Rri Monitoring
121
Rri Monitoring
122
Connecting the Lead Wire Set for 12-Lead Rri Monitoring
122
Rri Monitoring
123
Connecting the Lead Wires for Neonatal Rri Monitoring
123
Patient Preparation for Respiration Monitoring
123
Rri Monitoring
123
Patient Preparation for Respiration
124
Monitoring
124
Rri Display
125
Respiration Parameter Box
125
Respiration Markers
125
Rri Measuring Modes
126
Accessing the Rri Dialog Window
126
Rri Parameter Setup Functions
127
Connecting the Lead Wires for Neonatal
123
Advertisement
Dräger Infinity Acute Care System M540 Quick Reference Manual (24 pages)
Acute Care System
Brand:
Dräger
| Category:
Monitor
| Size: 1 MB
Table of Contents
Table of Contents
2
Contents
2
Trademarks
3
Side View of the M540
3
Dialogs
4
Calibrating the Touchscreen
4
To Select a View
4
Discharging a Patient
4
Selecting a New Patient Category
5
To Adjust the Alarm Volume
5
Pausing Acoustic Alarm Signals (Audio Pause)
5
Pausing Alarms at the M540
6
Pausing Alarm Monitoring Temporarily
7
Activating or Deactivating Alarm Monitoring
7
Setting the Upper and Lower Alarm Limits
8
Archive Function
8
To Access Stored Events
9
Electrode Placement
10
ECG Parameter Setup Functions
12
Respiration Parameter Setup Functions
14
Spo and Pulse CO-Ox Monitoring with Masimo
16
SET Mcable
16
Spo and Pulse Rate Monitoring with Nellcor
17
Oximax Mcable
17
Temperature Parameter Setup Functions
18
Non-Invasive Blood Pressure Parameter Setup Functions
19
To Assign a Pressure Label Manually
20
Zeroing a Specific Transducer
20
Invasive Pressure Parameter Setup Functions
21
Mainstream CO 2 Monitoring
22
Microstream CO 2 Monitoring
23
Dräger Infinity Acute Care System M540 Quick Reference Manual (24 pages)
Acute Care System
Brand:
Dräger
| Category:
Monitor
| Size: 0 MB
Table of Contents
Table of Contents
2
Electrode & Lead Placement
3
Terminology
7
Docking, Transport, Power, and Keys
8
Function Keys, Tabs, & Dialog Boxes
10
Patient Category, Admit and Discharge
12
Audio and Visual Alarms and Silencing
13
Alarm Priorities
14
Views, Waveforms and Parameters
15
Setting Parameter Alarm Limits
16
Parameter Specific Settings
17
Ecg
17
Nibp
18
Etco2
18
Spo2
19
Rri
19
12-Lead ECG
21
Invasive Pressures
22
Advertisement
Related Products
Dräger Infinity M500
Dräger Infinity M300+ series
Dräger MultiTest
Dräger Movita
Dräger Movita lift
Dräger Movita lift express
Dräger Movita lift strong
Dräger MP00349
Dräger MU10900
Dräger MU10898
Dräger Categories
Medical Equipment
Respiratory Product
Measuring Instruments
Test Equipment
Gas Detectors
More Dräger Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL