Dräger Infinity Cockpit C700 Quick Reference Manual

Dräger Infinity Cockpit C700 Quick Reference Manual

Infinity acute care system
Hide thumbs Also See for Infinity Cockpit C700:

Advertisement

Infinity Acute Care System
Quick Reference Guide
Infinity Cockpit
C700 / C500
This Infinity Quick Reference
Guide is not a replacement or
substitute for the Instructions for
Use (IFU). It is for informational
purposes
only.
Software Level: VG4

Advertisement

Table of Contents
loading

Summary of Contents for Dräger Infinity Cockpit C700

  • Page 1 Infinity Acute Care System Quick Reference Guide This Infinity Quick Reference Guide is not a replacement or substitute for the Instructions for Use (IFU). It is for informational Infinity Cockpit purposes only. C700 / C500 Software Level: VG4...
  • Page 2: Table Of Contents

    INFINITY COCKPIT QUICK REFERENCE GUIDE Content Electrode & Lead Placement Docking, Transport, Power and Keys Blue Header Bar, Quick Access & Function Keys 10-12 Patient Category and Admit Discharge, Standby and Privacy Alarm Priorities Alarm Pause & Alarm Setup 16-18 Screen Setup Restore Profile and Views 19-20 Parameter Setup...
  • Page 3: Electrode & Lead Placement

    INFINITY COCKPIT QUICK REFERENCE GUIDE Electrode & Lead Placement DO’S & DO NOT’S Do place the electrode on a clean and dry area of skin. Do utilize soap, water, and dry skin thor- oughly. Do remove hair if necessary for proper elec- trode placement.
  • Page 4 INFINITY COCKPIT QUICK REFERENCE GUIDE Electrode Colors* AHA/US Electrode Location Yellow Black Left arm Green Left leg White Right arm Black Green Right leg (neutral) White Brown Moveable chest Gray & White V+ Gray & Brown 2 Moveable chest Standard 6 Lead Configuration Standard 5 Lead Configuration THIS GUIDE IS INTENDED FOR REFERENCE ONLY.
  • Page 5 INFINITY COCKPIT QUICK REFERENCE GUIDE Standard 3 Lead Configuration Pacemaker Configuration 5 electrodes Warning: Make sure the pacemaker detection is turned OFF for patients without pacemakers and that it is ON for patients with pacemakers. Al- ways keep pacemaker patients under close surveillance. THIS GUIDE IS INTENDED FOR REFERENCE ONLY.
  • Page 6 INFINITY COCKPIT QUICK REFERENCE GUIDE 12-Lead Configuration (ten electrodes) Respiratory lead placement for infants THIS GUIDE IS INTENDED FOR REFERENCE ONLY. REFER TO INSTRUCTIONS FOR USE MANUAL.ADDITIONAL INFORMATION © 2015 Draeger Medical, Inc.
  • Page 7 INFINITY COCKPIT QUICK REFERENCE GUIDE Docking and Transport, Power & Frequently Used Keys M500 DOCKING STATION WITH M540 AND COCKPIT M500 secures and powers the M540 monitor M500 connects M540 to the Cockpit and the Infinity network that may include an Infinity Central Station (ICS), a network re- corder, and a network printer.
  • Page 8 INFINITY COCKPIT QUICK REFERENCE GUIDE COCKPIT Refers to the C500/C700 medical cockpit. The main user interface for the IACS TO POWER ON/OFF Press the Power On/Off key Select Shutdown inside the dialog window. The message System is shutting down appears on the screen while the Infinity Medical Cockpit is being powered down.
  • Page 9 INFINITY COCKPIT QUICK REFERENCE GUIDE AUDIO PAUSE KEY This key is located to the right of the rotary knob. Pauses acoustic alarm signals for two minutes. Note: Quiet Mode is Activated – If a new alarm condition with a priority higher than the currently paused alarm occurs, a truncated alarm tone sounds.
  • Page 10: Blue Header Bar, Quick Access & Function Keys

    INFINITY COCKPIT QUICK REFERENCE GUIDE Blue Header Bar, Quick Access Icons, & Function Keys BLUE HEADER BAR Appears along the top of the screen and displays the following: Patient category field (adult pediatric, neonate) System data field Patient name field Time and date field Alarm message field Alarm banner field...
  • Page 11 INFINITY COCKPIT QUICK REFERENCE GUIDE QUICK- ACCESS SYMBOLS Symbols that offer access to frequently used functions Quick access sym- Associate tool bar bol next to: All alarms off, or All alarms paused Auto set all ALARMS… Show all ECG Remote view Print screen VIEWS…...
  • Page 12 INFINITY COCKPIT QUICK REFERENCE GUIDE FUNCTION KEYS Preconfigured and Configurable quick access keys Function ALARMS Opens the Alarms dialog window. MARK EVENT Stores an event in the alarm history. CODE Executes pre-configured functions associat- ed with a code RELEARN ARR Establishes a new QRS template VIEWS…...
  • Page 13: Discharge, Standby And Privacy

    INFINITY COCKPIT QUICK REFERENCE GUIDE Patient Category, Admit, Discharge, Standby, and Privacy PATIENT CATEGORY Each patient category for Adult, Pediatric, and Neonate have specif- ic defaults associated with it. Touch patient category symbol left most field of the blue header bar on Cockpit. Select desired Patient category.
  • Page 14 INFINITY COCKPIT QUICK REFERENCE GUIDE TO DISCHARGE A PATIENT Select Discharge function key on the main menu bar. The message Caution discharge will delete patient data ap- pears. Select Discharge to confirm, or Cancel to resume monitoring same patient. The message Touch Screen to initiate monitoring appears. Note: All patient data is deleted upon discharge, and either factory or user default limit settings are restored.
  • Page 15: Alarm Priorities

    INFINITY COCKPIT QUICK REFERENCE GUIDE Alarm Priorities HIGH-PRIORITY ALARMS - Report conditions that can be life threatening and require imme- diate intervention; for example, asystole. - The alarming parameter’s box and alarm message field have red background, and audible alarms*sound when active. - Are latched, (audio / visual alarms continue until the alarm is acknowledged, even if the alarm condition has ceased to ex- ist).
  • Page 16: Alarm Pause & Alarm Setup

    INFINITY COCKPIT QUICK REFERENCE GUIDE Alarm Pause & Alarm Setup TO PAUSE AUDIO ALARMS FOR 2 MINUTES Press the yellow key on the Cockpit. Pressing the key again turns alarms back on Note: Quiet Mode is Activated – If a new alarm condition with a priority higher than the currently paused alarm occurs, a truncated alarm tone sounds.
  • Page 17 INFINITY COCKPIT QUICK REFERENCE GUIDE ARCHIVE FUNCTION In response to an alarm limit violation for each Parameter or Ar- rhythmia the following occurs depending on the Archive setting: o Off – no event is stored and no recording is generated. o Store –...
  • Page 18 INFINITY COCKPIT QUICK REFERENCE GUIDE CONFIGURING ARR (ARRYTHMIA) ALARM SETTINGS Select the Alarms button on the main menu bar. Select the Limits tab (if not already selected). Select the ARR tab along the right side. Select the corresponding setup button for the Alarm priority column to select the alarm priority.
  • Page 19: Screen Setup Restore Profile And Views

    INFINITY COCKPIT QUICK REFERENCE GUIDE Screen Setup, Restore Profile & Views DISPLAY MODE SETUP/AUTO VIEW TAB The Mainscreen of the Cockpit will show parameters and wave- forms based on two settings, Auto or Manual Select Setup button on far right of Auto display toolbar if available o OR, select System Setup from menu bar key, Screen Setup tab (on top), and Auto view tab (on right).
  • Page 20 INFINITY COCKPIT QUICK REFERENCE GUIDE TO SELECT OR RESTORE A PROFILE A profile consists of customizable pre-defined settings for each patient category, and may include settings unique for each parame- ter, the alarm defaults, and configurable menu bar keys. Default Profile is restored when selected or upon discharge.
  • Page 21: Ecg

    INFINITY COCKPIT QUICK REFERENCE GUIDE Parameters TO ACCESS ANY PARAMETER SETTINGS Select the desired parameter box. OR, if desired parameter is not visible Select Sensor parameters… on Main menu bar. 3. Select desired parameter tab from tabs across top of dialog box. Alarm settings Touch desired parameter box...
  • Page 22 INFINITY COCKPIT QUICK REFERENCE GUIDE TO TURN PACEMAKER DETECTION ON / OFF Select Heart rate parameter box. Select Settings 2 tab. At Pacer Detection select On or Off. If buttons are grayed out, make sure choice of Filter (locat- ed directly above Pacer detection) is not set to ESU TO ADJUST QRS DETECTION THRESHOLD Select the Heart rate parameter box.
  • Page 23: Rri/Impedance Respirations

    INFINITY COCKPIT QUICK REFERENCE GUIDE RRi - Impedance Respiration TO RELEARN RESP PROCESSING Select RRi parameter box. Select Relearn. RRi waveform is re-analyzed and saved as a reference for counting the Resp waveform. TO SELECT AUTO OR MANUAL MODE Select RRi parameter box. At Mode, select Auto or Manual to change.
  • Page 24: Spo2

    INFINITY COCKPIT QUICK REFERENCE GUIDE SpO2 Monitoring The accuracy of SpO2 monitoring depends largely on the strength and quality of the SpO2 signal TO CHANGE PULSE TONE VOLUME Select SpO2 parameter box. At Pulse tone volume %, select button. Dial rotary knob to select desired setting. Click rotary knob to confirm.
  • Page 25: Mainstream Etco2 Monitoring

    INFINITY COCKPIT QUICK REFERENCE GUIDE Note: Pressing the NIBP start/stop button longer than two seconds suspends interval mode and sets the Interval time [min] to Off. To resume interval times, must re-set to desired time interval and initiate by pressing NIBP Start / Stop.
  • Page 26 INFINITY COCKPIT QUICK REFERENCE GUIDE TO ZERO CO2 Only zero a Dräger sensor when the measurement value is suspect, or when you are prompted to re-zero on the monitor screen blue header bar. Remove sensor from airway adapter before attempting to zero.
  • Page 27 INFINITY COCKPIT QUICK REFERENCE GUIDE 12 Lead Monitoring Requires an additional 4 lead wire set be added to an existing 6 lead set. The12 lead option must be enabled and patient is admit- ted at ICS with Name, Height, Weight, and Birth date. TO OBTAIN A DIAGNOSTIC 12-LEAD (REST ECG) REPORT Select System setup...
  • Page 28: Invasive Pressures

    INFINITY COCKPIT QUICK REFERENCE GUIDE Invasive Pressures If no pressure labels are saved as default, labels GP1 to GP4 are automatically assigned. In Auto view when cables and transducers are connected IBP parameter box will be visible on Mainscreen. TO CHANGE A PRESSURE LABEL Select any invasive pressure parameter box.
  • Page 29: Cardiac Output

    INFINITY COCKPIT QUICK REFERENCE GUIDE Pulmonary Artery Wedge Pressure Select the PA parameter box or select the Procedures... button from the main menu bar. Select the Wedge tab or button. Check scale, sweep speed, and reference waveform selections and adjust as needed. Select the Prepare wedge button.
  • Page 30 INFINITY COCKPIT QUICK REFERENCE GUIDE o The computation constant is already entered except Other. a) If Other is selected, manually enter computation con- stant by selecting Comp. Constant [ ] b) Using adjacent on-screen keypad or keyboard, touch to enter numbers. c) Click rotary knob to confirm.
  • Page 31: Calculations

    INFINITY COCKPIT QUICK REFERENCE GUIDE Calculations TO PERFORM CALCULATIONS Select the Procedures... button from the main menu bar. Select Calculations tab o Touch Capture values. All necessary data available to the monitor will be captured. o To change or manually enter data, touch the value or values to be changed.
  • Page 32 INFINITY COCKPIT QUICK REFERENCE GUIDE HEADQUARTERS Dräegerwerk AG&Co. KGaA Moslinger Allee 53-55 23558 Lübeck, Germany www.draeger.com CANADA Draeger Medical Canada Inc, 2425 Skymark Ave Unit1 Mississauga, ON L4W 4Y6 +1 905 212 6600 Toll-free +1 866 343 2273 +1 905 Manufacturer: Draeger Medical Systems, Inc.