8.2.11

Timer Output Level Setting Register C (TOLR)

TOLR is an 8-bit write-only register that selects the timer output level for channels 0 to 2.
Bit
Initial value
Read/Write
Reserved bits
A TOLR setting can only be made when the corresponding bit in TSTR is 0.
TOLR is a write-only register, and cannot be read. If it is read, all bits will return a value of 1.
TOLR is initialized to H'C0 by a reset and in standby mode.
Bits 7 and 6—Reserved: These bits cannot be modified.
Bit 5—Output Level Setting B2 (TOB2): Sets the value of timer output TIOCB
Bit 5
TOB2
Description
0
TIOCB
is 0
2
1
TIOCB
is 1
2
Bit 4—Output Level Setting A2 (TOA2): Sets the value of timer output TIOCA
Bit 4
TOA2
Description
0
TIOCA
is 0
2
1
TIOCA
is 1
2
246
6
5
7
TOB2
1
1
0
W
4
3
2
TOA2
TOB1
TOA1
0
0
0
W
W
W
Output level setting A2 to A0, B2 to B0
These bits set the levels of the timer outputs
(TIOCA
to TIOCA
2
0
1
0
TOB0
TOA0
0
0
W
W
, and TIOCB
to TIOCB
2
.
2
(Initial value)
.
2
(Initial value)
)
0