Main tab: Status information
Advanced tab: Status information
Time Properties:
CHAPTER
5
SecureSync User Reference Guide Rev. 18
Ethernet Status : Whether the module is connected to a network through Ethernet.
Green =Connected. The speed of the connection is indicated.
Orange =Not connected.
Port State : Reports the current state of the PTP State Machine:
Disabled : PTP Ethernet port is Disabled. See PTP Setup/Network page, PTP Net-
work Settings options.
Initializing : Ethernet link is unplugged/PTP Module is in power-up state. A Master
Clock doesn't leave this state while it can't get the current time and synchronization
references from the SecureSync to synchronize with it.
Listening : PTP module is looking for a Master Clock.
Master : PTP Master has become the active Master Clock on the network.
Passive : PTP Module has become a Passive Master Clock. (There is another
Master Clock on the network with better quality or higher priority). This Master will
wait until the Best Master Clock Algorithm determines it should become the best
Master Clock, and then it will transition to the Master Clock state.
Uncalibrated : PTP Slave has selected a Master Clock on the network attempts to
synchronize with it using sync packets.
Number of Unicast Slaves : Number of PTP Slaves that have been granted by the PTP
Master to run in unicast mode.
Profile : Whether the profile is the default or Telecom.
Domain Number : The current PTP Domain Number.
Clock Mode : See "Main tab settings" on page 391.
Current IP Address : The IP address currently being used by the PTP interface.
MAC Address : The MAC address currently being used by the PTP interface.
UTC Offset : The Master's current offset between UTC time and TAI time. Units: seconds.
UTC Offset Valid : Indicates whether or not the Master's UTC Offset is valid.
Leap Second : The Leap second correction as set on the Time Management page.
Time Traceable : Indicates whether the Master's time is traceable (Enabled) to a primary
reference or not (Disabled).
Frequency Traceable : Indicates whether the Master's Frequency is traceable (Enabled)
to a primary reference or not (Disabled).