ues). If the year value is not present in the IRIG input signal, the year value will need to be manu-
ally set in SecureSync when using IRIG input as the only input Time reference.
The current year value can be manually entered from the MANAGEMENT/OTHER/Time Man-
agement page. The year value only needs to be manually entered once, as it will automatically
increment to the next year each New Year's day. See "Editing the System Time" on page 169 for
instructions on manually setting the current year.
5.4.2.9 Verifying IRIG Input Signal Validity
See: "Verifying the Validity of an Input Signal" on page 292.
5.4.2.10 IRIG Input: Status Window
To view the current settings of the IRIG Input (also referred to as 'Reference'), go to its Status win-
dow. For instructions, see: "Viewing the Configuration of an Input or Output" on page 288.
The Web UI list entries for these cards are: IRIG In/Out BNC and IRIG In/Out Fiber . The con-
nector number is: J1.
CHAPTER
•
5
SecureSync User Reference Guide Rev. 18
NOTE –
By default, the "year" fields in the IRIG message are ignored and a user-
defined value is used.
NOTE –
By default, the "year" fields in the IRIG message are ignored and a user-
defined value is used. Make sure the year is set correctly when the SecureSync is
installed. If the year is not set correctly before NTP achieves time synchronization, it
will use the value entered. The unit will also default to the year entered if it is
powered down during the rollover of the year. If the SecureSync was not switched on
during the rollover, this value must be updated.
NOTE –
When the IRIG Input year is updated,
Web UI NTP page (or the SecureSync unit rebooted) for the New Year value to take
effect.
SecureSync starts numbering I/O ports with 0 (only 1PPS and 10 MHz out-
NOTE –
puts start at 1, because of the built-in outputs).
5.4 Time Code Option Cards
NTP
must be restarted from the
345