5.5.2.1 PTP Grandmaster [-32]: Specifications
Figure 5-40:
5.5.2.2 PTP Grandmaster [-32]: Edit Window
1.
CHAPTER
5
SecureSync User Reference Guide Rev. 18
Inputs/Outputs : (1) Configurable as Input or Output
Signal Type and Connector : Ethernet via SFP, and 1PPS Output via BNC
Management : Web UI
Resolution : 8ns (±4ns) packet time stamping resolution
Accuracy : 30 ns accuracy (3σ) Master to Slave, via crossover cable
Network Speeds : 100 Mb/s, or 1Gb/s, depending on SFP module used
PTP Version supported: PTP 2 (IEEE 1588-2008)
PTP Profiles supported: Default, Telecom, Enterprise
Transmission modes : Unicast [default], Multicast
Maximum Number of Cards : 6
Ordering Information : 1204-32: PTP/Precision Timing Protocol Option Module
Model 1204-32 option card rear plate
To configure this option card, go to its Edit window. For instructions, see "Configuring the
Settings of an Input or Output" on page 290.