INSPECTION
Tester (Volt/ohmmeter)
For the inspection, use a tester having an internal resistance of
more than 10
knN.
Use of a tester with a low internal resistance may cause wrong
measurement or secondary troubles.
Conventional type connector
When resistance measurement and/or voltage measurement is
conducted at the connector section, insert the measuring probe
from the back of the connector, being very careful not to
damage the harness-to-terminal connections .
Water-proof
type
connector
When resistance measurement and/or voltage measurement is
conducted at the connector
secf1on,
bring the
measur"1ng
probe
into contact
with
the terminal at the connection side of the
connector.
Be very careful not to apply excessive force to the terminal at
the connector side. Failure to observe this caution may deform
the terminal, causing poor continuity.
As an alternative method, insert a male or female terminal into
the connector terminal or connect an adequate attachment.
Then, connect the measuring probe .
CONNECTION
Perform the connection, until the lock is completely engaged.
NOTE:
To confirm whether the lock
type
connector
has
been
locked or not, lightly pull the connector. Make sure that
the connector will not
be
disconnected.
Be sure to press the connector again before finishing the
confirmation .
HW-3
~
HARNESS
&
WIRING DIAGRAM
'<'<=?
l
WFE90-HW010

Advertisement