Daihatsu F300 Service Manual page 1428

Hide thumbs Also See for F300:
Table of Contents

Advertisement

EFISYSTEM
3. Immerse the heat sensing section of the intake air
tempera~
ture sensor in water. Raise the water temperature gradually.
Check to see
if the resistance varies within the specified
values in accordance with the table.
If the measured resistance will not conform to the specifica-
tions, replace the intake air temperature sensor.
Specifications
Water temperature
·c
Resistance
(k.n)
60
0.584±0.2
40
1.140±0.3
20
2.450
±
0.5
4. Check that there is no continuity between each terminal of
the intake air temperature sensor and the sensor body.
If
there is continuity,
replace the intake air temperature
sensor.
5. Install the intake air temperature sensor to the surge tank
with a new gasket interposed.
Tightening Torque:
29.4 - 39.2 N·m (3.0 - 4.0 kgf-m)
6. Connect the intake air temperature sensor connector.
EF-60