IP Address. Note: that if the Subnet Mask is set to 0.0.0.0, an IP Address of 0.0.0.0 matches all IP addresses. The default
value is 0.0.0.0
Client IP Mask - A mask to be ANDed with the requesting entity's IP address before comparison with IP Address. If the
result matches with IP Address then the address is an authentic cated IP address. For example, if the IP Address =
9.47.128.0 and the corresponding Subnet Mask = 255.255.255.0 a range of incoming IP addresses would match, i.e. the
incoming IP Address could equal 9.47.128.0 - 9.47.128.255. The default value is 0.0.0.0
Access Mode - The access level for this community string.
Status - The status of this community access entry.

8.5.18 show snmptrap

This command displays SNMP trap receivers. Trap messages are sent across a network to an SNMP Network Manager. These
messages alert the manager to events occurring within the switch or on the network. Six trap receivers are simultaneously
supported.
Format
show snmptrap
Mode
Privileged EXEC
SNMP Trap Name - The community string of the SNMP trap packet sent to the trap manager. This may be up to 16
alphanumeric characters. This string is case sensitive.
IP Address - The IP address to receive SNMP traps from this device. Enter 4 numbers between 0 and 255 separated by
periods.
Status - A pull down menu that indicates the receiver's status (enabled or disabled) and allows the administrator/user to
perform actions on this user entry:
Enable - send traps to the receiver
Disable - do not send traps to the receiver.
Delete - remove the table entry.

8.5.19 show trapflags

This command displays trap conditions. Configure which traps the switch should generate by enabling or disabling the trap
condition. If a trap condition is enabled and the condition is detected, the switch's SNMP agent sends the trap to all enabled trap
receivers. The switch does not have to be reset to implement the changes. Cold and warm start traps are always generated and
cannot be disabled.
Format
show trapflags
Mode
Privileged EXEC
Authentication Flag - May be enabled or disabled. The factory default is enabled. Indicates whether authentication
failure traps will be sent.
Link Up/Down Flag - May be enabled or disabled. The factory default is enabled. Indicates whether link status traps
will be sent. Multiple Users Flag.
Multiple Users Flag - May be enabled or disabled. The factory default is enabled. Indicates whether a trap will be sent
when the same user ID is logged into the switch more than once at the same time (either via telnet or serial port).