Application messages

Table 6
Application messages that appear on the console
Message
tschkhst: check_host: Cannot
open Tele-Server Profile
tschkhst: check_host: Cannot
retrieve services from
Tele-Server Profile
tsmain: write to trace file failed
tsmain - cannot open syslog
tsmain write to syslog failed
Cannot Start Link Process
Ôfile nameÕ: tsmain can't open
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 5: Application Module and IPE Module error messages 239
The following list is a summary of the messages displayed by applications
running on the Application Module or IPE Module.
Description
Indicates an internal application problem. Use
Procedure 2: SBC restart.
Indicates an internal application problem. Tell your
Nortel support personnel there is no service in
TSprofile and request new application software.
There is a problem writing to an application trace file.
The file system may be full. Log in as maint and enter
diskuse. Refer to the filedelete command if the disk
usage is greater than 95 percent. If the file system is
not full, restart the trace by logging in as mlusr and
entering untrace main followed by trace main.
Indicates an internal application problem. Use
Procedure 2: SBC restart.
There is a problem writing to the SysLog file. The file
system may be full. Log in as maint and enter
diskuse. Refer to the filedelete command if the disk
usage is greater than 95 percent.
At least one of the link processes (mlnk HDLC, hlnk
HDLC, hlink X25, lh or lhrx) is missing from
/usr/mlusr/bin, or is for some reason not executable.
Reinstall the application.
There is a problem opening a trace file in the
/usr/mlusr/trace directory. The file system may be full.
Log in as maint and enter diskuse. Refer to the
filedelete command if the disk usage is greater than
95 percent.