Nortel Meridian Meridian 1 Maintenance Manual page 339

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

For duplicate call IDs, a call arrived with the same identification
number as an existing call. This situation is likely to point to a
software error, (old calls in the system are not being cleaned up).
Restart the application.
5: For the specific conditional branches that executed for this call,
the first statement encountered by call processing was a QUIT or
WAIT statement. These are not valid first treatments, so the call
was handed to Meridian 1 for processing. Correct the script.
2012
Log message
Meridian 1
Parameters
Description
controlÓ below) issued by the Meridian 1 indicates that the inbound
traffic flow exceeds configured limits. The limits can be changed, or
the system is temporarily operating above its capacity. This situation is
cleared by a subsequent flow control level 0 indication.
Messages may be lost if the condition persists.
Impact
Check configuration parameters on Meridian 1 and change
Recovery
them if necessary, especially if this occurs under normal call volume.
If the configuration is correct and the problem persists, it indicates the
system is running above capacity.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 7: CCR log file messages 327
Flow control level 2 indication received from the
None
A flow control level 2 indication (see ÒNotes on flow

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meridian 1

Table of Contents