Table 13
maint messages that appear in the SysLog file (continued)
Command
Message
restart
(no messages)
rstdata
Restore unsuccessful
scriptinfo
No ccr_scriptinfo file available
scriptinfo failed:
MULTILANGUAGE_ERR
scriptinfo failed: MEMORY_ERR
scriptinfo failed:
ASSOCTABLE_ERR
scriptinfo failed: FILEOPEN_ERR
tapeinfo
Extracting information from the
tape...
version
(no messages)
viewlog
(no messages)
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 5: Application Module and IPE Module error messages 285
Ñ end Ñ
Description
ErrorÑthe restore data operation
was not successful. The problem
is most likely with the tape media.
Verify that the tape is positioned in
the drive correctly, and that it is
write-enabled. Wait for the LED to
go out after inserting the tape
before executing the command.
The scriptinfo data file is not
present, indicating possible file
system damage.
The multilanguage feature is not
working properly for the scriptinfo
feature, indicating possible file
system damage.
No memory is available for the
scriptinfo feature, indicating
possible file system damage.
A memory error or Association
Table open failure occurred,
indicating possible file system
damage.
An error occurred while a file was
being opened, indicating possible
file system damage.
StatusÑthis is a normal message
before the list of tape information.