Table 7
maint messages that appear on the console (continued)
Command
Message
ccrstart
ERROR: CCR terminated due to
memory allocation failure
ERROR: CCR terminated due to a
problem reading the AMprofile.
ERROR: CCR terminated due to
invalid CCR packaging.
WARNING: Max active
associations for installed CCR has
been exceeded. All associations
deactivated.
Customer Controlled Routing was
not started successfully
One or more Customer Controlled
Routing processes are already
running
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 5: Application Module and IPE Module error messages 247
Ñ continued Ñ
Description
There is not enough available
memory for CCR to execute
successfully. Reboot the system.
The system profile cannot be read
or may be corrupted. CCR will not
execute correctly. It is likely the
software was not installed properly.
The system profile may be
corrupted. CCR will not execute
correctly. It is likely the software
was not installed properly.
The CCR data contains an
association table that has more
active associations than are allowed
for the installed CCR package. All
associations have been changed to
the Ò
state. The user may enter
OFFÓ
a CCR user session and manually
activate up to the active association
limit for the installed CCR.
The application was not started.
Use the viewlog command to search
for any applicable errors in the
SysLog file.
CCR has already been started. Any
subsequent attempt to start CCR,
once it has been started, will not
actually start it again.