Procedure 22: Load the application software from tape (continued)
22
You are prompted for the name of the Application Module or
IPE Module. (The term Òmodule nameÓ refers to an Ethernet host
computer, which in this case is the Application Module or IPE
Module.) Type the module name and press [Return]. The module
name must not exceed eight alphanumeric characters. For more
information about module names, consult your network
administrator.
Figure 142
Module address prompt
Enter the MODULE ADDRESS to be added to the tcpip transport provider database
(?, or module address):
23
You are prompted for the address of the Application Module or IPE
Module (Figure 142). Type the module address and press [Return].
The module address must be four numbers separated by periods,
such as Ò12.234.67.89Ó. For more information about module
addresses, consult your network administrator.
Figure 143
Reenter prompt
If you made any mistakes in entering the module name and IP address, you can
correct them. Would you like to re-enter the module name or IP address? [y,n]:
24
You are asked whether you want to reenter the module name or
address (Figure 143).
If you have not made a mistake, type n and press [Return]. Go to
step 25.
If you want to reenter the module name and address, type y and
press [Return]; you will return to step 22.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 8: Recovery/replacement procedures 451