Nortel Meridian Meridian 1 Maintenance Manual page 309

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

0B02 - Facility already enabled
Facility is already enabled and an attempt is made to turn on the same
message facility. No action is necessary.
0B03 - Facility already disabled
Facility is already disabled, and an attempt is made to turn off the same
message facility. No action is necessary.
0B04 - Message(s) already set
A message is already set, and an attempt is made to set the same
message. No action is necessary.
0B05 - Message(s) already cleared
A message is already cleared, and an attempt is made to clear the same
message. No action is necessary.
0B06 - Unable to open/write/close recording file
Unable to open/write/close a recording file in /usr/mlusr/rec directory.
Make sure that mlusr has both read and write access to /usr/mlusr/rec.
0B07 - Invalid message type specified in MLUSR command
Verify that the message type specified is a valid Meridian Link
message. Use help ÔmsgtypeÕ, help ÔmessageÕ, or help ÔcommandÕ to
display valid messages.
0B08 - Cannot clear all message set (filter, monitor or record)
To rectify this problem, shut down and restart the application
(including the Meridian Link application).
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 6: Link error messages 297

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meridian 1

Table of Contents