Nortel Meridian Meridian 1 Maintenance Manual page 304

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

292 Chapter 6: Link error messages
553-3211-510 Standard 1.0 October 1998
These errors are corrected by full specification of the command option.
Refer to Chapter 3, ÒLink maintenance commandsÓ or use the online help
facility (for example, help trace) for more information on each command.
A second class of errors occurs due to error conditions existing within the
Meridian Link software. The first of these errors occurs when mlusr is
unable to register with the Meridian Link software. If the registration
message times out, the following message is displayed:
AM Base software not responding: mlusr/admin
unable to register. Is Meridian Link/AM Base
software installed and running? Reboot the system
to recover.
To correct this error, restart the Meridian Link software by rebooting the
Application Module or IPE Module.
Meridian Link software errors are a result of an mlusr request that cannot
be properly processed. A message indicates the error condition and a
description is printed on the mlusr screen. Error messages are displayed in
the following format:
Error <Error Number>: <Error Description>
For example:
Error 0x0906: Link already enabled
See Òmlusr error messagesÓ for the action to be taken in response. (The 0x,
which indicates hexadecimal, is not listed with the error messages in this
guide.)
The following message appears if the X.25 communications software has
crashed and the links are being reconfigured:
<date and time> Meridian Link Panic: Link failure -
reconfigure links