9
Check the Application Module MVME333-2 XCC card jumper
settings as follows:
¥
Perform Procedure 3: Hardware powerdown.
¥
Perform Procedure 11: Replace the MVME333-2 XCC card
(without actually replacing the card).
¥
Perform Procedure 4: Power up the Application Module or IPE
Module.
TCP/IP host computer link (Link 1) will not establish
This section applies to Meridian Link only.
The following section describes the steps to take if the TCP/IP Host Link
between the host computer and the Application Module or IPE Module
does not establish.
Check link status from the Meridian Link.
¥
Log in as mlusr. If unable to log in, see the section ÒLogin failureÓ
earlier in this chapter.
¥
Check the status of the link by typing status link 1 in the mlusr
prompt.
If the response is ÒLink 1 : UpÓ, the Host Link is properly connected
and the problem is not the Host Link connectivity. Make sure the host
application has properly registered (see ÒApplication registration
failsÓ).
If the response is ÒLink 1 : Enabled but downÓ, it is possible that no
applications are registered.
Ñ Perform a loopback test as described in Chapter 3, ÒLink
maintenance commandsÓ. If there is no response to the ping
command, contact your system administrator.
Ñ Restart the application.
If neither of the above steps gives you the message ÒLink 1: UpÓ,
contact your Nortel support personnel.
If the response is ÒLink 1 : DisabledÓ, enable the link by typing
enable link1 in the mlusr prompt.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 4: Diagnosing faults 225