374 Chapter 8: Recovery/replacement procedures
553-3211-510 Standard 1.0 October 1998
Procedure 8: Configure the Application Module MVME147 SBC card
(continued)
3
Write down the release level of the monitor/debugger (known as
firmware level). In Figure 20, this is shown as 2.42. This number will
be used later in this procedure.
Figure 21
Start-up interrupt menu
1) Continue System Start-up
2) Select Alternate Boot Device
3) Go To System Debugger
4) Initiate Service Call
5) Display System Test Errors
6) Dump Memory to Tape
Enter Menu #:
4
The start-up interrupt menu appears. Type 3 and press [Return] to
enter the system debugger.
5
At the Ò147-Diag>Ó prompt, type iot;t and press [Return].
The system performs a scan of disk/tape controllers. Figure 22
shows the results of the scan.
Figure 22
Results of disk/tape controller scan
Scanning system for available disk/tape controllers........
Disk Controllers Available
LUN
Type
Address
0
VME147
$FFFE4000
1
VME147
$FFFE4000
VME147
$FFFE4000
Align LUNs to SCSI addresses [Y,N] N?
6
Write down the type of disk drive installed in SCSI address 0. This
information is required later in the procedure. (In the example
shown above, the drive is a CDC ST1126N.)
7
You are prompted to align LUNs. Type y and press [Return].
# dev
1
SCSI Addr = 0 - CDC
1
SCSI Addr = 4 - TEAC
*
SCSI Addr = 7
ST1126N
9204
MT-2ST/N50
RV D