Nortel Meridian Meridian 1 Maintenance Manual page 197

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

If ÒLoading: Operating SystemÓ is not displayed, UNIX was probably not
installed correctly. If it is determined that UNIX was not installed correctly,
go to ÒSoftware reinstallationÓ for installation instructions.
Loading: Operating System
If ÒLoading: Operating SystemÓ is the last message displayed and the
system seems to be frozen, the SCSI bus may need to be reset. Perform
Procedure 2: SBC restart, and type h while the firmware tests are being run.
At the Ò167-DiagÓ or Ò4120-DiagÓ prompt, type reset and press [Return].
Answer y to the first prompt, c to the second prompt, and n to the third
prompt.
Volume:
IPL loaded at:
$001F0000
MVME TAPE IPL Version 1.0
*********************************************************************
System V/68 Release R3V7 M68030 Version 920526
*********************************************************************
Copyright (c) 1984-1992 Motorola Inc. All rights reserved
Init: Single User Mode
erase = #
kill = @
***
Enter <CR> to pause in a single user shell before init.
The system issues a series of messages as it starts up. When start-up is
complete, the system displays the ÒConsole Login:Ó prompt.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Real mem
= 6291456
Avail mem = 4964352
Buffers
= 60
intr = DEL
quit = ^|
Chapter 4: Diagnosing faults 185