Nortel Meridian Meridian 1 Maintenance Manual page 69

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

Chapter 2: Application Module commands 57
Example 2: System has no default gateway and no subnet mask pre-
configured, and has NSE running
maint> lanconfig
Default gateway is not currently configured!
If you would like a default gateway IP address configured or changed,
please enter the IP address in Internet dot notation (e.g. 12.34.56.78).
For no change, enter <cr>.10.20.30.40
Saving default gateway address: 10.20.30.40
Subnet Mask is not currently configured!
If you would like a default gateway subnet mask configured or changed,
please enter the subnet mask (e.g. 100.100.0.0).
For no change, enter <cr>. 100.100.200.0
Saving default subnet mask: 100.100.200.0
ADD MODULE NAME AND ADDRESS TO TCPIP TRANSPORT
PROVIDER DATABASE
If you are not sure how to answer any prompt, type "?" for HELP.
Your module is already specified in the transport provider database:
Its module name: python. Its IP address: 123.0.0.4
Would you like to change them? [y, n] n
The name and address for your module are not changed.
If you've made any changes to the Ethernet configuration,
you need to reboot the system in order for new changes
to take effect.
Would you like to reboot the system now? [Enter Y for Yes or N for No]: y
Running subcommand 'reboot' for menu 'machinemgmt',
MACHINE MANAGEMENT
Once started, a reboot CANNOT BE STOPPED.
Do you want to start an express reboot? [y, n, ?, q] y
Shutdown started ...
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide