Nortel Meridian Meridian 1 Maintenance Manual page 461

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

Procedure 22: Load the application software from tape (continued)
Figure 138
CCR customer number prompt
Please enter the CCR customer number (0-99):
20
You are prompted to enter your CCR customer number
(Figure 138). Type the number and press [Return].
Note: A two-minute pause occurs at this point before the following
messages appear.
Figure 139
Ethernet connection prompt
Installing NSE R3V7.1. Please wait.
Is your module connected to the Ethernet (y/n) ?
21
You are asked whether your Application Module or IPE Module is
connected to Ethernet (Figure 139).
For more information about Ethernet connections, refer to
Chapter 9, ÒMeridian Link/CCR interface cablingÓ chapter of the
Meridian Link/Customer Controlled Routing Installation and
Upgrade Guide (NTP 553-3202-210).
If your module is not connected to Ethernet, type n and press
[Return]. Go to step 25.
If you are connected to Ethernet and you plan to use it in the near
future, type y and press [Return]. You see a message asking you to
wait. Then you see more installation messages (Figure 140). Go to
step 22.
If you are connected to Ethernet but do not plan to use it in the near
future, you may choose to type n and press [Return]. Disabling
Ethernet support increases the processing power available to your
application(s). Go to step 25.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 8: Recovery/replacement procedures 449