Nortel Meridian Meridian 1 Maintenance Manual page 65

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

Chapter 2: Application Module commands 53
Example (continued):
Note: The configuration specified is displayed, as shown in the following
example.
The following applications are configured:
Meridian Link
Large CCR
The following packages are configured:
1
96
97
98
99
100
101
Ethernet NSE software is enabled.
Is this correct (y/n/q)?: y
Note: Enter y to enable the NSE software, n to return to the keycode
entry prompt, or q to exit without enabling.
Please enter the CCR customer number (0-99): 1
Installing NSE R3V7.1. Please wait.
Is your module connected to the Ethernet (y/n) ? y
Configuring your system for NSE, please wait.
... various configuration and sysgen messages appear ...
ADD MODULE NAME AND ADDRESS TO TCPIP TRANSPORT
PROVIDER DATABASE
If you are not sure how to answer any prompt, type Ò?Ó for HELP.
Your moduleÕs system is currently the default name. We recommend that
you change it to avoid possible name conflicts.
Enter the MODULE NAME to be added to the tcpip transport provider
database (?, or module name): ipename
Enter the MODULE ADDRESS to be added to the tcpip transport provider
database (?, or module address): 12.34.56.78
Ñ continued Ñ
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide