read link

Use this command to reconfigure a link from the parameters saved in a file.
If you do not provide a file name, the file name specified in the link control
file is used. Configuration files can be read from any specified directory.
You are asked to confirm the parameters. A ÒyesÓ response to the confirm
prompt reconfigures the link. A ÒnoÓ response aborts the command.
Command format:
mlusr> read link link_number [filename]
Note: The maximum length of the file name is 14 characters. The file
name must follow a slash character; for example, /saveconfig1.
Example:
To reconfigure link number 1 from file saveconfig1:
mlusr> read link 1 /saveconfig1
Protocol: X25
Machine ID: x25dest
Delay: 0
Port type: X
PDN type: 44
Baud rate: 19200
RFS timer: 150
Remote address: 3
Maximum out frames (K): 7
Local DTE address: 000000990100
Flow control negotiation: 0
Outgoing packet size: 128
Outgoing window size: 2
Incoming throughput class: 10
Lowest LCN for DTE/DCE: -1
Lowest LCN: 1
LOC LIC: -1
T10: 1800
T11: 2000
T13: 1800
T15: 1500
Maximum T12 retries: 3
Confirm? (yes or no): y
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 3: Link maintenance commands 115
Link type: 2
Physical DTE(0)/DCE(1): 1
Maximum Frame length: 135
Fail timer: 150
Internal address: 1
T1: 30
Maximum trans attempts (N2): 7
Incoming packet size: 128
Incoming window size: 2
Throughput negotiation used: 0
Outgoing throughput class: 10
Highest LCN for DTE/DCE: -1
Highest LCN: 4095
HOC HIC: -1
T12: 1800
T14: 600
T16: 1300
Maximum T13 retries: 3