Nortel Meridian Meridian 1 Maintenance Manual page 341

Application module and intelligent peripheral equipment module meridian link release 5c/ccr release 3c diagnostic and maintenance guide
Hide thumbs Also See for Meridian Meridian 1:
Table of Contents

Advertisement

2013
Log message
Meridian 1. Refer to ÒNotes on flow control,Ó CCR message 2012.
Parameters
Description
controlÓ following message 2012) was issued by the Meridian 1
indicating that the Meridian 1 inbound traffic flow consistently
exceeded configured limits. The system may be temporarily operating
above its capacity. A subsequent flow control level 0 indicates when
the system is again operating at normal capacity.
Messages will be lost until the condition is cleared.
Impact
If flow control indication does not return to 0, especially if
Recovery
the situation occurs when call volume is below normal, check
configuration parameters on Meridian 1 and change them if necessary.
If the configuration is correct and the problem persists, it indicates the
system is running above capacity.
2014
Log message
many times
Parameters
Description
software keeps the same error from logging in the log file. Once the
same event is logged five times consecutively, message 2014 appears
when the sixth request is received. This event is not logged again until
another event is received and logged. The intent is to keep runaway
errors from crippling the system.
No operational impact
Impact
Investigate why the error preceding this event occurred
Recovery
repeatedly and clear the problem.
Meridian Link Release 5C/CCR Release 3C Diagnostic and Maintenance Guide
Chapter 7: CCR log file messages 329
Flow control level 3 indication received from the
None
A flow control level 3 indication (see ÒNotes on flow
Previous event suppressed when it was repeated too
None
An error message filtering function in the event logging

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meridian 1

Table of Contents