3.5 Connecting Remote Master

The iNEX is designed to sense 12-volts DC from a master switch, which
when configured will activate the treatment recording function on the
iNEX.
It is recommended that the Remote Master is connected to an existing
master switch in the vehicle, however there are many options including
12-volts DC from a master valve, an implement switch or a separate
toggle switch.
1. Connect a wire to the 12-volt positive on/off source, such as an
existing master switch.
2. Connect the other end of the wire to the Remote Master (brown
cable) on the iNEX Vehicle Cable.
3. Consult the iNEX user manual for instruction on configuring the
system to use the Remote Master as the master source.
Note: The iNEX will detect 12-volt positive as the master being on and no power as
the master being off.

3.6 Connecting Remote Input

The Remote Input can be connected to a momentary push-button switch
which can then remotely trigger a user defined function on the iNEX, such
as engage/disengage auto steering.
1. Connect 12-volts to one side of a momentary push-button switch.
2. Connect a wire from the other side of the momentary push-button
switch to the Remote Input (white cable) on the iNEX Vehicle Cable.
3. Consult the iNEX user manual for instruction on configuring the
Remote Button function to be triggered by the Remote Input.
Note: The 12-volts DC supplied to the Remote Master and the Remote Input MUST
be on the same 12-volt DC circuit to which the iNEX is connected.
iNEX Installation Manual