Table 5-6. Switch Settings For Dtmf Detection Timing, Vau; Table 5-7. Switch Settings For Wait Timing Between Dialed Digits, Vau - Panasonic CPC-EX Installation Manual

Digital business system section 300 (applies to cpc-aii/b version 9.2 and cpc-ex version 2.3)
Table of Contents

Advertisement

Section 300-Installation
Table 5-7. Switch settings for delay answer timing, VAU
Table 5-8. Switch settings for DTMF detection timing, VAU
Table 5-9. Switch settings for wait timing between dialed digits, VAU
DBS-2.3/9.2-300
Switch Block 2 (SW2)
Delay Answer Timer (Switches 1-3)
Switch
4
8
1
OFF OFF OFF OFF ON
2
OFF OFF ON
3
OFF ON
DTMF Detection Timer
VAU
Switch
Version
block and
switch
1.1 or above
SW2, pin 4
1.0 or below
SW1, pin 1
and SW2,
pin 4
Switch Block 2 (SW2)
Wait Time Between Dialed Digits (Switches 5-6)
Switch
5
6
DBS Manual - Revised April 2000
Chapter 5. Peripheral Equipment
Timer (in seconds)
16
12
20
24
ON
ON
OFF OFF ON
OFF ON
OFF ON
ON=80 ms
OFF=40 ms
Where X/X=SW1 setting/SW2 setting:
ON/ON=40
OFF/ON=60
ON/OFF=80
OFF/OFF=100
Time (in seconds)
2
6
OFF
OFF
OFF
ON
28
No Answer
(VAU 1.1 or
below) or
Immediate
Answer (VAU
1.2 or above)
ON
ON
ON
OFF ON
Function
10
14
ON
ON
OFF
ON
5-23