Vlan-Acl Troubleshooting; Introduction To Mirror - Planet XGS3-42000R User Manual

4-slot layer 3 ipv6/ ipv4 routing chassis switch
Table of Contents

Advertisement

3)
Configure the extended acl_b of IP, at any time it only allows to access resource wit hin the int ernal
network (such as 192.168.1.255).
XGS 3-42000R(config)#ip access-list extended vacl_b
XGS 3-42000R(config-ip-ext-nacl-vacl_a)# permit ip any-source 192.168.1.0 0. 0.0.255
XGS 3-42000R(config-ip-ext-nacl-vacl_a)# deny ip any-source any-destination
4)
Apply the configuration to VLAN
XGS 3-42000R(config)#vacl ip access-group vacl_a in vlan 1
XGS 3-42000R(config)#vacl ip access-group vacl_b in vlan 2

55.4 VLAN-ACL Troubleshooting

When VLA N ACL and P ort ACL are configured at the same time, the principle of denying firstly is used.
When the packets match VLAN ACL and Port ACL at the same time, as long as one rule is drop, then the
final action is drop.
Each ACL of different types can only apply one on a V LAN, such as the basic IP A CL, each V LAN can
applies one only.

55.5 Introduction to Mirror

Mirror functions include port mirror function, CPU mirror function, flow mirror function.
Port mirror refers to the duplication of data frames sent/received on a port to another port. The duplicated port
is referred to as mirror source port and the duplicating port is referred to as mirror destination port. A protocol
analyzer (such as Sniffer) or a RMON monitor will be connected at mirror destination port to monitor and
manage the network, and diagnose the problems in the network.
CPU mirror function means that the switch exactly copies the data frames received or sent by the CPU to a
port. Flow mirror function means that the switch exactly copies the data frames received or by the specified
rule of a port to another port. The flow mirror will take effect only the specified rule is permit.
A Chassis Switch supports at most 4 mirror destination ports, each boardcard allows a source or destination
port of a mirror session. At present, each box switch can set many mirror sessions.For 5950 series box
switches, many mirror s essions are not supported by XGS3-24040-52T/ XGS 3-24040-52T-L. There is no
limitation on mirror source ports, one port or several ports is allowed. When there are more than one source
ports, they can be in the same V LAN or in different VLAN. The source port and destination port can be in
different VLA N.
box switch can't use CP U's rx mirror and port 's tx mirror at the same time.
55-4