increased, which means a reduced bandwidth.
ULDP does not handle any LACP event. It treats every link of TRUNK group (like Port-channal, TRUNK
ports) as independent, and handles each of them respectively.
ULDP does not compact with similar protocols of other vendors, which means users can not use ULDP
on one end and use other similar protocols on the other end.
ULDP function is disabled by default. After globally enabling ULDP function, the debug switch can be
enabled simultaneously to check the debug information. There are several DEBUG commands
provided to print debug information, such as information of events, state machine, errors and messages.
Different types of message information can als o be printed according to different parameters.
The Recovery timer is disabled by default and will only be enabled when t he us ers have configured
recovery time (30-86400 seconds).
Reset command and reset mechanism can only reset the ports automatically shut down by ULDP. The
ports shut down manually by users or by other modules won't be reset by ULDP.
10-11