6. Click Close on the Diagnostic Port Test dialog box.
Brocade Network Advisor SAN User Manual
53-1002167-01
TABLE 43
Status Detail messages
Operation/Test
Disable the source or destination
port
Enable the diagnostic mode on
source or destination E ports
Enable the source or destination
port
Disable the diagnostic mode on
source or destination D ports
Lost connectivity to switch while
test is in progress
Diagnostic port test timed out
The Management application
waits 30 minutes to complete
the test. If not completed, the
test times out.
Electrical Loopback Test
Optical Loopback Test
Link Traffic Test
Distance between ports
Possible message
Disabled the port slot_number/port_number of the switch
switch_IP_address.
Failed to disable the port slot_number/port_number of the switch
switch_IP_address.
Reason: CAL_error_message
Enabled diagnostic mode on port slot_number/port_number of the
switch switch_IP_address.
Failed to enable diagnostic mode on port slot_number/port_number of
the switch switch_IP_address.
Reason: CAL_error_message
Enabled the port slot_number/port_number of the switch
switch_IP_address.
Failed to enable the port slot_number/port_number of the switch
switch_IP_address.
Reason: CAL_error_message
Disabled diagnostic mode on port slot_number/port_number of the
switch switch_IP_address.
Failed to disable diagnostic mode on port slot_number/port_number of
the switch switch_IP_address.
Reason: CAL_error_message
Connection failed to the switch during the operation.
Diagnostic port test time-out. You may need to change the port
configuration before retrying.
Successfully completed Electrical Loopback Test on port
slot_number/port_number of the switch switch_IP_address.
Electrical Loopback Test failed on port slot_number/port_number of the
switch switch_IP_address.
Electrical Loopback Test skipped on port slot_number/port_number of
the switch switch_IP_address.
Reason: CAL_error_message
Successfully completed Optical Loopback Test.
Optical Loopback Test failed
Optical Loopback Test skipped.
Reason: CAL_error_message
Successfully completed Link Traffic Test.
Link Traffic Test failed.
Approximate distance between the ports is numerical_value meters.
26
FC troubleshooting
755

Advertisement

Table of Contents
loading

This manual is also suitable for:

Network advisor 11.1.xBrocade bladesystem 4/24

Table of Contents