E
Database tables and fields
TABLE 235
Field
CREATION_TIME
LAST_SCAN_TIME
LAST_UPDATE_TIME
SYSLOG_REGISTERED
CALL_HOME_ENABLED
SNMP_REGISTERED
USER_IP_ADDRESS
NIC_PROFILE_ID
MANAGING_SERVER_IP_
ADDRESS
VF_ENABLED
VF_SUPPORTED
MANAGED_ELEMENT_ID
NAT_PRIVATE_IP_ADDRESS
ALTERNATE_IP_ADDRESS
1068
CORE_SWITCH (Continued)
Definition
Time when this record was created by the
Management application.
Default is 'now()'.
Time when this record was last updated.
1 = the Management application server is registered
with the switch to receive Syslog.
Default is 'now()'.
1 = Syslog is enabled for this switch.
Default value is 0.
1 = call home is enabled for this switch.
Default value is 1.
1 = the Management application server is registered
with the switch to receive SNMP traps.
Default value is 0.
User-assigned IP address. This is used for M-EOS
switches where Fabric OS seed switch fails to get the
IP address of the M-EOS switch.
NIC profile of the Management application server
host used by this switch to communicate in
interactive configuration and other operations. It
determines which Management application host IP
used by this switch.
IP address(v4/v6) of the Management applciation
server which is currently managing the M-model
switch. Used for M-EOS switch only. It does not apply
to Fabric OS switches.
Default value is 0.
Default value is 0
A unique managed element ID for this physical
switch. Also a foreign key reference to the
MANAGED_ELEMENT table.
NAT private IP Address. Feature available from NMS
DC Eureka release onwards. During a successful NAT
translation the Private IP that gets translated will be
stored in this field. The new translated IP Address will
be stored in the existing IP_ADDRESS field. All the
NAT look up will be done using the NAT Private IP
Address.
Alternate IP address of the switch. Feature available
from Eureka release onwards. During fabric discovery
the column will be populated based on the values in
the fabricinfo.html. If Management applciation server
is IPV6 capable, then we store the switchetherIP NVP
else we store the switchetherIPV6. So could be either
IPV4 or IPV6 address. If there exists any NAT
translation, translated IP will be used.
Format
timestamp
timestamp
timestamp
smallint
smallint
smallint
varchar
int
varchar
smallint
smallint
int
varchar
varchar
Brocade Network Advisor SAN User Manual
53-1002167-01
Size
128
128
128
128