31
Viewing a policy monitor report
970
Fabric Checks — Fabric checks provide the following information for each selected check:
Name — Fabric name.
Status — Result of the check and reason for failure if known. Valid results include
Passed, Partially Failed, Failed, Not Applicable, and Unknown.
Fabric checks include the following options:
Check zoning is enabled
Check that all zones belong to at least one zone configuration
Check the number of initiator ports zoned to each storage port is less than
Configured_Value. This check provides the following additional detail for this check:
-
Storage Port — WWN of the storage port.
-
Initiator Count — Number of initiator ports zoned to the storage port.
-
Initiator Port — WWN of the initiator port.
-
Zone — Zone name containing the initiator/storage port zoning pair.
Switch Checks — Switch checks provide the following information for each selected check:
Name — Product name.
Status — Result of the check and reason for failure if known. Valid results include
Passed, Partially Failed, Failed, Not Applicable, and Unknown.
Switch Checks include the following options:
Switch — Check for at least Configured_Minimum_Value connections to neighboring
switches. This check provides the following additional detail for this check:
-
Neighboring Switch — Name of the neighboring switch.
-
Connection Count — Number of connections to the neighboring switch.
Switch — Check for HTTPS (secure HTTP) configuration. This check provides the
following additional detail for this check:
-
HTTPs Status — Whether HTTPS is enabled or disabled on the product.
-
HTTP Status — Whether HTTP is enabled or disabled on the product.
Switch — Check if the product is configured to send events to this server.
Switch — Check if the product is configured to send Upload Failure Data Capture to an
FTP server.
Switch - Check for SSH (secure Telnet) configuration.This check provides the following
additional detail for this check:
-
SSH Status — Whether SSH is enabled or disabled on the product.
-
Telnet Status — Whether Telnet is enabled or disabled on the product.
Brocade Network Advisor SAN User Manual