Show Interface - Cisco MDS 9124 - Fabric Switch Reference

Cisco mds 9000 family command reference - cisco mds san-os release 3.0(1) through 3.3(1a) (ol-16217-01, april 2008)
Hide thumbs Also See for Cisco MDS 9124 - Fabric Switch:
Table of Contents

Advertisement

show interface

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Table 22-5
Interface Type
bay port | ext port
cpp slot/port
fc slot/port
fc-tunnel tunnel-id
fcip interface-number
fv slot/dpp-number/fv-port
gigabitethernet slot/port
gigabitethernet slot/port.
subinterface-number
iscsi slot/port
mgmt 0
port-channel
port-channel-number
port-channel
port-channel-number
.subinterface-number
sup-fc 0
vsan vsan-id
Examples
The following example shows how to display information about a Fibre Channel interface.
switch# show interface fc1/11
fc1/11 is up
Cisco MDS 9000 Family Command Reference
22-142
Interface Types for the show interface Command
Hardware is Fibre Channel
Port WWN is 20:0b:00:05:30:00:59:de
Admin port mode is ST
Port mode is ST
Port vsan is 1
Speed is 1 Gbps
Rspan tunnel is fc-tunnel 100
Beacon is turned off
5 minutes input rate 248 bits/sec, 31 bytes/sec, 0 frames/sec
5 minutes output rate 176 bits/sec, 22 bytes/sec, 0 frames/sec
6862 frames input, 444232 bytes
0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
6862 frames output, 307072 bytes
Description
Displays information for a Fibre Channel interface on a Cisco Fabric
Switch for HP c-Class BladeSystem or a Cisco Fabric Switch for IBM
BladeCenter.
Displays information for a virtualization interface.
Displays the Fibre Channel interface in the specified slot/port.
Displays description of the specified FC tunnel from 1 to 4095.
Specifies a FCIP interface. The range is 1 to 255.
Displays information for the virtual F port (FV port) interface in the
specified slot along with the data path processor (DPP) number and the
FV port number.
Displays information for a Gigabit Ethernet interface at the specified slot
and port.
Displays information for a Gigabit Ethernet subinterface at the specified
slot and port followed by a dot (.) indicator and the subinterface number.
The subinterface range is 1 to 4093.
Displays the description of the iSCSI interface in the specified slot and
port.
Displays the description of the management interface.
Displays the PortChannel interface specified by the PortChannel number.
The range is 1 to 128.
Displays the PortChannel subinterface specified by the PortChannel
number followed by a dot (.) indicator and the subinterface number. The
port channel number range is 1 to 128. The subinterface range is 1 to
4093.
Displays the in-band interface details.
Displays information for a VSAN. The range is 1 to 4093.
Chapter 22
Show Commands
OL-16217-01, Cisco MDS SAN-OS Release 3.x

Advertisement

Table of Contents
loading

Table of Contents