Chapter 17
O Commands
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
out-of-service xbar
To perform a graceful shutdown of the external crossbar switching module of a Cisco MDS 9513
Director, use the out-of-service xbar command in EXEC mode.
Syntax Description
slot
Defaults
None.
Command Modes
EXEC.
Command History
Release
3.0(1)
Usage Guidelines
Before removing a crossbar from an MDS 9500 Series Director, you must perform a graceful shutdown
of the crossbar.
The administrator must enter the EXEC mode out-of-service xbar command for a graceful shutdown of
the external crossbar switching module in a Cisco MDS 9513 Director.
The slot refers to the external crossbar switching module slot number.
To reactivate the external crossbar switching module, you must remove and reinsert or replace the
Note
crossbar switching module.
Taking the crossbar out-of-service may cause supervisor switchover.
Caution
For additional information about crossbar management, refer to the Cisco MDS 9000 Family CLI
Configuration Guide.
Examples
The following example shows how to perform a graceful shutdown of the external crossbar switching
module of a Cisco MDS 9513 Director.
switch# out-of-service xbar 1
OL-16217-01, Cisco MDS SAN-OS Release 3.x
out-of-service xbar slot
no out-of-service xbar slot
Specifies the external crossbar switching module slot number, either 1 or 2.
Modification
This command was introduced.
out-of-service xbar slot
Cisco MDS 9000 Family Command Reference
out-of-service xbar
17-27