REP 56.10.2 Sensor Bracket

Parts List on
PL 56.10
Removal
When turning OFF the power switch, check that the 'Data' lamp is OFF and that there is
no Job in progress.
Turn OFF the power switch and make sure that the screen display turns OFF.
Check that the power switch is OFF and unplug the power plug.
1.
Remove the DADF Front Cover.
(REP
2.
Remove the DADF Rear Cover.
(REP
3.
Remove the Invert Chute.
(REP
56.9.3)
4.
Remove the Bracket and Ground Plate at the front. (Figure 1)
(1) Remove the Tapping Screw (x3).
(2) Loosen the screw.
(3) Remove the Bracket and Ground Plate.
Figure 1 j0lj45636
Initial Issue
WorkCentre 5021/5019
WARNING
56.2.1)
56.2.2)
NOTE: Be careful so as to not lose the gear under the Bracket and Ground Plate. (Figure
2)
5.
Remove the Knob Handle. (Figure 3)
(1) Remove the gear.
(2) Remove the Knob Handle.
6.
Remove the Bearing of the DADF Takeaway Roll. (Figure 4)
(1) Remove the KL-Clip.
(2) Remove the Bearing.
08/2012