Action
Pull the cables out and route the cable in the
movable chain end.
Fix the cables with straps on the cable chain ac-
cording to the photo taken before the replacement.
Refit the cable drawer and secure with screws.
Reconnect all connectors according to the dia-
gram.
Use a spirit level to check that the chain is level
in the tray.
If needed, adjust the leveling bolts or shim the
brackets that hold the tray.
Switch on the power and jog all axes to check that
the cabling is correctly connected.
Check that all process cabling and hoses are
working properly.
Run a few strokes in jogging mode and check that
the chain is gliding properly upon itself and is
correctly adjusted sideways.
© Copyright 2023 ABB. All rights reserved.
Note
xx2200000879
xx2200000878
Screws: ISO 4762 M8x20 Class 8.8
(4 pcs)
Washers: BN 792 M8 Washer (4
pcs)
Tightening torque: 25 Nm