ABB IRT 710 Product Manual page 212

Table of Contents

Advertisement

4 Maintenance
4.5.2 Automatic lubrication system
Continued
2
3
4
5
6
Continues on next page
212
Action
Pull-up the black rubber seal. Fill-in the Memol-
®
ub
with a manual grease pump. This manual
operation is required only if the Memolub has
been used without a cartridge, if the previous
cartridge has run out of grease. Place the pump
nipple at the entry of the Memolub, and pump
until you see grease coming out at the outlet. Two
strokes of the manual pump are usually enough.
Pull-up the black strap to reveal the battery case.
Insert a new Memolub battery: hold it by the black
plastic strap & insert it in the Memolub respecting
the instructions on the label. If the battery is cor-
rectly inserted the motor is activated during 1 sec.
to check that the motor is working properly. Put
the black rubber seal back in place.
Remove the paper disc from the replacement
cartridge. Fill-in the required dates: "Started" and
"Replace before". The "replace before" date is
depending on the Memolub program. Put the pa-
per disc back in place in order to see the instruc-
tions when the Memolub is closed.
Press softly on the cartridge until the grease
comes out, to avoid injecting air into the pump.
Place the cartridge at the inlet of the pump. Check
that the cartridge is correctly inserted in the inlet
of the pump.