3HKA00000186299-001 Revision: B
Action
Verify that there is a clearance of approximately
6 mm between the rack covers and the rack (see
figure).
If not, unscrew the cover screws and push the
cover away from the rack. Tighten the cover
screws.
Move the carriage to both ends in manual mode
at low speed. Verify that the cable chain is not
rubbing on the covers during the carriage move-
ment, and that no moving part shows abnormal
wear. Check also that the stationary cables are
not interfering with moving elements.
Check that the cable chain is long enough to reach
the ends of the stroke without damage. At least 1
chain link should remain horizontal to avoid unne-
cessary pulling on the chain fixing element. Verify
again that the chain is parallel with the cable tray
when unwind. If not, adjust the orientation of the
fixed point of the chain as described in step5.
© Copyright 2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.3 Installation of the cable chain
Note/Illustration
xx2200001260
Continued