5 Repair
5.4.2.2 Replacing the inner cable chain link
Continued
Removing the inner cable chain link
1
2
3
Continues on next page
296
Action
DANGER
Turn off all electric power, hydraulic and pneumat-
ic pressure supplies to the robot and for the track
motion.
Insert the screwdriver into the slot to pry the
plastic link bar.
Note
A 5 mm screwdriver is recommended.
Or the plastic link bar may be broken.
Note
Be careful with the direction when prying.
Or the plastic link bar cannot be pried off.
Remove the plastic link bars besides the cable
chain link which need to replace.
© Copyright 2023 ABB. All rights reserved.
Note
xx2200000845