3 Installation and commissioning
3.4.7.2 Recommendations for floor mounting
Continued
Installation of chemical anchors
Please respect the following procedure for chemical anchors installation. No
mechanical anchors allowed. Chemical anchors used in IRT 710 is HILTI M16x125
anchors.
1
2
3
Continues on next page
130
Action
Drill the hole with rotary hammer and set the depth
gauge to the correct drilling depth.
Diamond coring: Mark the correct drilling depth
on the height adjustment mechanism.
Clean the hole immediately before setting the
anchor. Remove drilling dust and standing water
from the base of the hole by blowing out well with
at least 4 strokes of the blow-out pump, or using
compressed air or an industrial vacuum cleaner.
The anchor holes must be free of dust, water, ice,
oil, bitumen, chemicals or any other foreign matter
or contaminants. Poorly-cleaned holes leads to
poor hold.
Ensure that the specified setting depth is marked
on the anchor rod. If not, add an embedment
mark, for example with tape or marker.