5 Repair
5.3.2 Replacing the rectangular rails
Continued
Required consumables
Consumable
Locking liquid
Flange sealant
Removing the rectangular rails
Use this procedure to remove the rectangular rails.
Preparations before removing the rectangular rails
1
2
3
Removing the rectangular rail
1
2
Continues on next page
268
Action
If there is no enough space for the maintenance
work, clean the surroundings.
If there is any robot on the track, jog it to the lift-
ing/transportation position.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the product, before entering the safeguarded
space.
Action
Remove the covers over the rectangular
rails to change.
Remove the rectangular rail by removing
all the screws.
© Copyright 2023 ABB. All rights reserved.
Article number
Note
-
Loctite 2400 (or equivalent Loctite
243)
-
Loctite 574
Note
Note
xx2200000831
3HKA00000186299-001 Revision: B
Product manual - IRT 710