3 Installation and commissioning
3.4.6 Moving the carriage manually
Continued
Release the brake (external 24V DC)
If there is no voltage to the motor, 24V DC can be connected direct to the SMB
box.
1
2
Continues on next page
118
Note
Care should be taken when moving the track manually.
Users should remain clear of these locations when moving the track.
xx1800001868
xx2200000666
Action
Unplug the Motor power cable from the SMB box that runs to the IRT 710 motor.
Using pins, connect the +24VCC to the G pin (see figure).