Memolub manual
The procedure below is based on the Memolub HPS user manual. It details how
to replace the grease cartridge.
Opening and closing the Memolub
1
2
Installing a new grease cartridge
Respect the following instructions to replace the grease cartridge:
1
Product manual - IRT 710
3HKA00000186299-001 Revision: B
Action
Check that no pipe has been damaged, and that
the grease is distributed to each block and on the
pinion.
After installing the lubrication feedback system,
check the lubrication status regularly (at least for
three months) to avoid incorrect feedback.
Action
Opening the Memolub.
First place the Memolub on a flat and clean sur-
face. Push firmly with one hand on top of the
Memolub. With the other hand, hold the black
base and turn counterclockwise. Pull the transpar-
ent bell to open.
Closing the Memolub.
Use the same technique: hold the cranked black
base, put the transparent bell and turn it clock-
wise. When the closed position is reached you
should hear a "click".
Action
®
Open the Memolub
as described before.