3 Installation and commissioning
3.4.7.3 Geometric alignment of track motion IRT 710
Continued
Alignment in Z direction
The figure shows the possible variation along the Z-axis.
The track should be laser aligned to within 0.1 mm from the origin per meter, along
the entire X-axis.
xx2200000787
Alignment in Y direction
The figure shows the possible variation along the Y-axis.
The track should be laser aligned to within 0.1 mm from the origin per meter, along
the entire X-axis.
xx2200000788
Procedure
1
2
3
Continues on next page
134
Action
On the foundation where the track will be placed,
use a laser line drawing instrument to draw the
approximate position of the installation position.
Place the track on the drawing position without
installing the anchor bolts.
Position the absolute tracker such as you will be
able to measure the reflector position on the linear
rails.
Make sure that the absolute tracker is parallel to
the sea level.
© Copyright 2023 ABB. All rights reserved.