7.6 Outline of Analog Signal Output Circuit

The analog signal output circuit can be used only for the FCUA-DX120/DX121/DX140/DX141.
Output circuit
Output conditions
Downloaded from
ManualsNet.com
7. CONNECTION OF REMOTE I/O UNIT
7.6 Outline of Analog Signal Output Circuit
220Ω
A0
A0*
Output voltage
Resolution
Load conditions
Output impedance
search engine
R
R
DAC
OV(LG)
0V to ± 10V ( ± 5%)
12bit ( ± 10V × n/4096) (Note)
10k Ω load resistance
220 Ω
(Note) n = (2
I -97
0
11
to 2
)

Advertisement